Magnetic suspension hip joint: an ideal design of an artificial joint 被引量:1

Magnetic suspension hip joint: an ideal design of an artificial joint
原文传递
导出
摘要 Background Artificial joints present certain problems such as osteal absorption and lysis induced by wear debris which leads to loosening of the prosthesis over a period of time. Here we propose a design of an artificial magnetic suspension joint that was prepared by integrating the medical theories of modern material science, magnetism, and medical physics.Methods According to clinical characteristic of biological and mechanical for hip joint, we designed the appearance and dimensions of magnetic suspension joint and placed neodymium-iron-boron permanent magnets in the prosthesis.As the same time, we performed mechanical and biological experiments using artificial magnetic suspension hip joints models.Results By simulated the human hip structure and the external load, we discovered the artificial magnetic suspension hip joints models had much lesser amount and size of wear debris than the ceramic/ceramic artificial hip joint prosthesis in friction wear tests. The force between the artificial joints with magnetic materials that we have calculated is feasible for application of artificial joint. The design of artificial magnetic suspension hip joints models was plausible technically and safe biologically.Conclusion Artificial magnetic suspension hip joints may effectively reduce the incidence of the loosening of prosthesis over a period of time. Background Artificial joints present certain problems such as osteal absorption and lysis induced by wear debris which leads to loosening of the prosthesis over a period of time. Here we propose a design of an artificial magnetic suspension joint that was prepared by integrating the medical theories of modern material science, magnetism, and medical physics.Methods According to clinical characteristic of biological and mechanical for hip joint, we designed the appearance and dimensions of magnetic suspension joint and placed neodymium-iron-boron permanent magnets in the prosthesis.As the same time, we performed mechanical and biological experiments using artificial magnetic suspension hip joints models.Results By simulated the human hip structure and the external load, we discovered the artificial magnetic suspension hip joints models had much lesser amount and size of wear debris than the ceramic/ceramic artificial hip joint prosthesis in friction wear tests. The force between the artificial joints with magnetic materials that we have calculated is feasible for application of artificial joint. The design of artificial magnetic suspension hip joints models was plausible technically and safe biologically.Conclusion Artificial magnetic suspension hip joints may effectively reduce the incidence of the loosening of prosthesis over a period of time.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第23期3451-3454,共4页 中华医学杂志(英文版)
关键词 artificial joint magnetic suspension aseptic loosening OSTEOLYSIS artificial joint magnetic suspension aseptic loosening osteolysis
  • 相关文献

参考文献1

二级参考文献48

共引文献51

同被引文献4

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部