摘要 目的研究自主改进的Mapleson-D型(麦氏D型)呼吸回路在短小手术静脉麻醉中的使用效果。方法选择112例在静脉麻醉下行门诊短小手术患者,ASAⅠ~Ⅱ级,随机分为2组,每组56例。A组术中使用普通面罩吸氧,发生呼吸抑制时换用急救呼吸器进行人工辅助通气;B组使用改进型麦氏D型呼吸回路吸氧,发生呼吸抑制时用该呼吸回路行人工通气。记录两组患者术中呼吸频率(RR)、血氧饱和度(SpO2)、呼气末CO2分压(PETCO2),及呼吸抑制患者的发生时间(T1)、纠正时间(T2)。结果使用改进型麦氏D型呼吸回路患者呼吸抑制的总体发生率低于普通面罩吸氧组,低氧血症的发生率较低,且纠正时间也较短。结论与普通吸氧面罩比较,改进型麦氏D型呼吸回路使用简便,发生呼吸抑制程度较轻且纠正迅速,在短小手术静脉麻醉的呼吸管理中较有使用价值。 Objective To assess the clinical effect of modified Mapleson D breathing system in intravenous anesthesia for minor surgical procedures.Methods A total of 112 patients (ASA Ⅰ-Ⅱ) scheduled for minor outpatient surgery were randomly divided into two groups,with 56 in each group.Patients in Group A inhaled oxygen using common face mask,and were transferred to artificial ventilation by emergency ventilator when respiratory depression occurred; those in Group B were subjected to modified Mapleson D breathing system,and were transferred to artificial ventilation using the present breathing system when respiratory depression occurred.The respiratory rate (RR),oxygen saturation (SpO2),Partial end-tidal CO2 pressure (PETCO2),occurrence (T1) and rectification time (T2) of respiratory depression were all recorded in the two groups.Results The incidence of respiratory depression in Group B was lower than that in Group A; moreover,Group B also had a higher incidence of hyoxemia and shorter rectification time compared with Group A.Conclusion Compared with conventional face mask,our modified Mapleson D breathing system is easy and convenient to use,and it leads to lower incidence and quick rectification of respiratory depression,showing a potential in the airway management of patients undergoing minor intravenous anesthesia.
出处 《第二军医大学学报》 CAS CSCD 北大核心 2010年第12期1353-1355,共3页 Academic Journal of Second Military Medical University
基金 上海市卫生局基金(2010155)~~
关键词 静脉麻醉 呼吸抑制 麦氏D型呼吸回路 气道管理 intravenous anesthesia; respiratory depression; Mapleson D breathing system; airway management;
  • 相关文献

参考文献5

  • 1Khan E I, Ullah H, Kamal R. Anaesthesia at remote location.. use of modified Bain Circuit (Mapleson D) at Kunri Christian Hospital[J]. J Pak Med Assoc,2009,59:445 -448.
  • 2Hillman D R, Platt P R, Eastwood P R. The upper airway during anaesthesia[J]. Br J Anaesth,2003,91 : 31-39.
  • 3Metzner J, Domino K B. Risks of anesthesia or sedation outside the operating room: the role of the anesthesia care provider [J]. Curr Opin Anaesthesiol, 2010,23 : 523-5:31.
  • 4Mapleson W W. The elimination of rebreathing in various semiclosed anaesthetic systems[J]. Br J Anaesth, 1954,26 : 323- 332.
  • 5郑小锋.麻醉通气系统的结构和原理[J].徐州医学院学报,2008,28(9):627-630. 被引量:2

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部