摘要
采用一体化生物反应器-消毒工艺处理大庆地区某医院污水,处理效果良好且工艺运行稳定。介绍了工艺流程、主要设备及工艺的调试及运行。运行结果表明:出水COD、氨氮、SS分别低于50,10,15 mg/L,均满足设计要求,地埋式一体化生物反应器适合高寒地区医院等行业污水处理。
In this research,the hospital sewage was treated by the process of integrated bioreactor and disinfection,which had a good treatment effect and stability.The process flow,major equipments and operation were introduced.The results showed that COD,NH3-N and SS of the effluent were lower than 50 mg /L,10 mg /L and 15 mg /L respectively,which had come up to the demand of design.The integrated bioreactor under ground was suited to the treatment of hospital sewage and other industries sewage in the arctic areas.
出处
《环境工程》
CAS
CSCD
北大核心
2010年第6期8-10,共3页
Environmental Engineering
基金
国家"十一五"重大科技专项(2008ZX07208-008)
辽宁省教育厅高等学校科研项目(2009T069)