摘要
针对频率标准用超导腔的设计,通过理论分析及编程计算得到了影响微波腔指标的参数,并对不同温度下微波腔的品质因数(Q值)进行计算得到了温度变化曲线,通过此曲线可以确定达到指标所需要的温度。所设计的微波腔参数为:工作模式为TM010模式,直径D为60mm,高度1为50mm,频率为4.4GHz,Q值在液氦温度4.2K时达到3.9×10^7,在减压降温到2K时达到1.9×10^9,实验结果与计算结果吻合。
To design a superconducting cavity with high quality factor for frequency standard, the parameters that affect the ability of the cavity are all achieved through theory analysis and computer program. A curve through which the temperature can be achieved for the aim is got through calculating the quality factor in different temperature. The parameters of cavity are as follows : the mode is TM010, the diameter is 60 mm, the height is 50 mm, the frequency is 4. 4 GHz, the quality factor is 3.9×10^7 and 1.9×10^9 when the temperature is 4. 2 K and 2 K, respectively, which is close to the calculation.
出处
《计量学报》
CSCD
北大核心
2011年第1期70-74,共5页
Acta Metrologica Sinica
关键词
计量学
频率标准
振荡器
低温学
超导腔
品质因数
Metrology
Frequency standard
Oscillator
Cryogenics
Superconducting cavity