简要介绍10~110kV建筑变电所的新设备及新技术,详细介绍10~35kV低电阻接地系统接地电阻的选择、接地故障保护的设置与整定。
This paper briefly introduces the new equipments and technology of the 10 - 110 kV building substation, and describes the selection of grounding resistance for the 10 - 35 kV low resistance grounding system in detail, as well as the set and setting of grounding fault protection.