摘要
介绍了房间空调器采用三元非共沸混合制冷剂R407C替代R22的试验研究结果.试验中对制冷剂充灌量、毛细管长度以及冷凝器与蒸发器的结构型式作了变动.初步试验结果表明:在冷凝器与蒸发器均加以改造后的房间空调器中采用R407C比原机采用R22时,制冷量增加1.7%,能效比降低1.5%.
Experimental studies are carried out with R407C, a kind of ternary non azerotropic alternative refrigerant for R22, in a room air conditioner. During the tests, the refrigerant charge size, length of capillary tubes and structure of condenser and evaporator are changed. Preliminary results indicate that cooling capacity with the mixture is 1.7 % higher, energy efficiency ratio 1.5 % lower in the modified equipment than those with R22.
出处
《西安建筑科技大学学报(自然科学版)》
CSCD
1999年第2期134-137,共4页
Journal of Xi'an University of Architecture & Technology(Natural Science Edition)
关键词
空调器
替代工质
制冷量
能效比
工质
room air conditioner, alternative refrigerant, cooling capacity, energy efficiency ratio