期刊文献+

FASTRAK在高密度头相关传输函数测量中的应用

FASTRAK Application of Head-related Transfer Function Measuring with High Density
下载PDF
导出
摘要 高密度头相关传输函数测量对声源空间方位的精度有更高要求,因此要有精度较高的声源定位装置(系统),并对定位系统的误差进行校准。使用FASTRAK电磁追踪器对测量高密度HRTF的定位系统进行误差校准。FASTRAK的空间分辨率为0.01°,静态精度为0.15°,经定位系统精度校准后,声源方位角误差可控制在0.1°±0.15°的范围内。文中测量高密度HRTF数据库的最小方位角间隔为2.5°,上述误差基本满足测量要求。 The measurement of head-related transfer function(HRTF) with high directional density requests high precision in sound source position.A sound source orientated system with high accuracy and corresponding error correction procedure are needed.In this paper,a FASTRAK electromagnetic pursue tracer is used to calibrate the error of high precision HRTF measurement orientated system.The spatial resolution of FASTRAK can arrive at 0.01°,and static state precision is 0.15°.After calibrating the directional precision,the error of sound source azimuth is controled within 0.1°±0.15°.The minimal azimuth interval of HRTF to be measured in the work is 2.5°,so that the directional accuracy of the designed system meets the requirement of the measurement.
出处 《电声技术》 2010年第12期45-47,共3页 Audio Engineering
基金 国家自然科学基金项目(10774049) 华南理工大学自然科学基金项目(x21xe5090450)
关键词 FASTRAK电磁追踪器 头相关传输函数 定位系统 FASTRAK electromagnetic pursue tracer HRTF orientated system
  • 相关文献

参考文献7

  • 1ZHONG X L, XIE B S. Maximal azimuthal resolution needed in measurements of head-related transfer functions [J]. J. Acoust. Soc. Am., 2009,125(4):2209-2220.
  • 2钟其柱,余光正,谢菠荪.用于高空间分辨率头相关传输函数测量的声源*·论文·[J].电声技术,2010,34(11):53-56. 被引量:1
  • 3BOVBJERG B P, CHRISTENSEN F, MINNAAR P, et al. Measuring the head-related transfer functions of an artificial head with high directional resolution [C]//Proc. AES 109 th Convention. Los Angeles, USA :AES, 2000: 5246.
  • 4GENUIT K, XIANG N. Measurements of artificial head transfer functions for auralization and virtual auditory environment[C]//Proc. 15th International Congress on Acoustics. Trondheim, Norway:[s.n.], 1995 : Ⅱ469-472.
  • 5TATSUYA H, HIROYUKI S. Head movement during headrelated transfer function measurements[J]. Aeoust. Soe.&Tech. 2010,31 (2) : 165-171.
  • 6POLHEMUS C. 3 space FASTRAK user's manual[R]. Vermont, USA:Polhemus, 2005.
  • 7谢菠荪,钟小丽,饶丹,梁志强.头相关传输函数数据库及其特性分析[J].中国科学(G辑),2006,36(5):464-479. 被引量:19

二级参考文献28

  • 1钟小丽,谢菠荪.头相关传输函数的研究进展(一)[J].电声技术,2004,28(12):44-46. 被引量:26
  • 2ZHONG Xiaoli, XIE Bosun. Maximal azimuthal resolution needed in measurements of head-related transfer functions [J]. Journal of the Acoustical Society of America, 2009,125 (4) : 2209-2220.
  • 3ALGAZI V R, DUDA R O. The CIPIC HRTF database[C]// Proc.2001 IEEE Workshop on Applications of Signal Processing to Audio and Acoustics. [S.L]: IEEE Press, 2001 : 99-102.
  • 4GARDNER W G, MARTIN K D. HRTF measurements of a KEMAR[J]. Journal of the Acoustical Society of America, 1995, 97(6) :3907-3908.
  • 5MLLER H, SRENSEN M F, JENSEN C B, et al. Transfer characteristics of headphones measured on human ear[J]. Journal of the Acoustical Society of America, 1995, 43(5): 300-321.
  • 6XIE Bosun, ZHONG Xiaoli, RAO Dan, et al. Head-related transfer function database and its analyses[J]. Science in China Series G :Physics, Mechanics & Astronomy,2006,36 (5) :464-479.
  • 7GENUIT K, XIANG N. Measurements of artificial head transfer functions for auralization and virtual auditory environment[C]//Proc. 15th International Congress on Acou- stics (invited paper).Trondheim, Norway: [s.n.], 1995 : 469- 472.
  • 8BOVBJERG B P, CHRISTENSEN F, MINNAAR P, et al. Measuring the head-related transfer functions of an artificial head with high directional resolution[C]//Proc. AES 109th Convention. Los Angeles. USA: AES,2000: 5246.
  • 9朱哲民,龚秀芬,杜功焕.声学基础[M].南京:南京大学出版社,2006.
  • 10山本武夫.扬声器系统[M].王以真,吴光威,译.北京:国防工业出版社,1984.