期刊文献+

氢化物原子荧光法测定废水中砷和硒 被引量:1

HGAFS Determination of Arsenic and Mercury in the Waste Water
下载PDF
导出
摘要 建立双道氢化物发生-原子荧光法同时测定废水中砷和硒的方法,对测定的影响因素:样品前处理及共存离子的干扰、预还原剂用量的选择、盐酸浓度、硼氢化钾浓度等试验条件作了研究并予以优化。在最佳条件下,方法的相对标准偏差(n=6)<10%,砷、硒加标回收率分别在95%~98%和90%~95%之间,标准物质的测定与标准值相符。 To establish the simultaneous dctermination of Arsenic and Mercury in the waste water by hydride generation atomic fluorescence spectrometry(HGAFS). Influential factors to the determination, including sample pretreatment, and interferences of coexisting ions, amount of reducing agent amount of potassium borohydrid added and HC1 added, ect were stuided and optimized.Working conditions in the assay, the RSD(n-6) of the method was less than 10 %. The recovery rates ranged of arsenic from 95 % to 98 %, mercury from 90 % to 95 %. The detecting results for standard materials were very. much close to the reference valucs.
出处 《广东化工》 CAS 2010年第12期135-136,共2页 Guangdong Chemical Industry
关键词 氢化物原子荧光法 废水 hydride generation atomic fluorescence spectromctry waste water arscnic mercury
  • 相关文献

参考文献4

二级参考文献4

共引文献62

同被引文献8

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部