摘要
总结在工作中使用阀控型密封铅酸蓄电池直流系统所遇到的调试及设计使用上的问题。分别从直流设备系统配置,直流电源系统技术要求,直流系统基本接线,阀控型密封铅酸蓄电池的常见应用问题,阀控型密封铅酸蓄电池直流系统设备的选择与计算等的角度,较为全面地阐述了在应用阀控型密封铅酸蓄电池直流系统时所遇到的技术要点及解决办法。
The problems encountered in the adjustment,design and application of valve controlled seal lead acid battery were summarized.From the respects of disposition of direct current system,the technical specification of direct current system,basic wiring of direct current system,common problems occurred in valve controlled seal lead acid battery and selection and calculation of valve controlled seal lead acid battery,the important technical points in using valve controlled seal lead acid battery were described overall.
出处
《医药工程设计》
2010年第6期49-52,共4页
Pharmaceutical Engineering Design
关键词
阀控型密封铅酸蓄电池
直流系统
深度放电
直流断路器
核对性放电
valve controlled seal lead acid battery
direct current system
deep discharge
direct cutout
checking discharge