期刊文献+

窑街煤矸石综合利用热电厂的成功运行 被引量:3

Success operation of Yaojie thermo-electric power plant designed for comprehensive utilization of coal refuse
下载PDF
导出
摘要 窑街劣质煤热电厂采用的4台130 t/h CFB锅炉,从建设到运行过程,科研、制造和应用单位合作攻关,采用多项新技术,锅炉运行稳定可靠,主要运行参数达到或优于设计值。取得了显著的节能降耗效果,并获得了很好的社会效益、环保效益和经济效益。 4 sets of 130 t/h CFB boiler installed at Yaojie inferior coal thermo-electric power plant;from its construction to operation,research institute,manufacturer and consumer closely cooperated to tackle key problems and several new techniques employed;as a result,boilers operated stably and reliably,main operation indices meeting those by design or even better,remarkable effects achieved in reduction of energy consumption and pollutant emission,and good social,economic and environmental benefit attained.
作者 庞树明
出处 《煤炭加工与综合利用》 CAS 2010年第6期49-50,共2页 Coal Processing & Comprehensive Utilization
关键词 热电厂 煤矸石 综合利用 效益 thermo-electric power plant coal refuse comprehensive utilization benefit
  • 相关文献

同被引文献34

引证文献3

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部