每搏变异度监测胸腔镜手术患者单肺通气时血容量变化的准确性 被引量:14

Accuracy of stroke volume variation in monitoring blood volume during one-lung ventilation in patients undergoing thoracoscopy operation
原文传递
导出
摘要 目的 评价每搏变异度(SVV)监测胸腔镜手术患者单肺通气时血容量变化的准确性.方法 择期行胸腔镜手术患者22例,性别不限,年龄18~60岁,体重51~77 kg,ASA分级Ⅰ或Ⅱ级.麻醉诱导后置入双腔支气管导管,行双肺机械通气,进胸前改为单肺通气,通气参数:潮气量8 ml/kg,通气频率10~14次/min,吸呼比1∶2,氧浓度100%,PEEP 0,维持PETCO2 35~40 mm Hg.分别于双肺通气5 min和单肺通气30 min时进行容量负荷试验,于10 min内静脉输注6%羟乙基淀粉(HES)5 ml/kg.于双肺通气时输注HES前即刻和输注HES结束后3 min(T1.2)、单肺通气时输注HES前即刻和输注HES结束后3 min(T3.4)时,记录MAP、HR、CO、和SVV,计算CI及SVV和CI的变化率(△SVV和CI).△CI≥11%为扩容有效,绘制SVV判断血容量变化的ROC曲线,计算曲线下面积(AUC)及其95%可信区间(95%CI).结果 与输注HES前即刻比较,输注HES结束后CO升高,SVV降低(P<0.05).双肺通气时△SVV与△CI呈负相关,相关系数为-0.710(P<0.05).ROC曲线分析结果示:SVV监测血容量变化的阈值为11.5%,灵敏度为82%,特异度为92%,AUC为0.880(95%CI 0.580~0.987).单肺通气时△SVV与△CI呈负相关,相关系数为-0.668(P<0.05).ROC曲线分析结果示:SVV监测血容量变化的阈值为9.5%,灵敏度为77%,特异度为63%,AUC为0.971(95%CI 0.917~1.024).结论 单肺通气并不会影响SVV监测胸腔镜手术患者血容量变化的准确性. Objective To evaluate the accuracy of stroke volume variation (SVV) in monitoring blood volume during one-lung ventilation in patients undergoing thoracoscopy operation. Methods Twenty-two ASA Ⅰ or Ⅱ patients ( 12 male, 10 female) aged 18-60 yr undergoing thoracoscopy operation under general anesthesia were studied. Anesthesia was induced with midazolam, sufentanil, propofol and rocuronium and maintained with TCI of propofol and remifentanil and intermittent iv boluses of vecoronium. Robertshow double-lumen endobronchial tube was inserted. Correct position of the tube was verified by fiberoptic bronchoscopy. The patients were mechani40 mm Hg. Radial artery was cannulated and connected to FloTrac pressure transducer and Vigileo monitor. A loading dose of 6% HES 5 ml/kg was infused over 10 min. MAP, HR, CO and SVV were recorded before and at 3 min after loading dose. The change rate of SVV (SVV) and CI (△CI) were calculated. Increase in CI by 11% was considered effective volume expansion. The ROC curve for SVV in determining the volume expansion efficacy was plotted. The area under the curve for SVV and 95% confidence interval were calculated. Results (1) CO were significantly increased while SVV decreased after a loading dose of HES. (2) During two-lung ventilation 12 patients responded to the 6% HES loading dose.SVV correlated with△CI ( - 0.710, P 〈 0.05). The volume expansion efficacy was determined by SVV 11.5 % (sensitivity = 82 %, specificity = 92 % ). The area under the curve for SVV and 95% confidance interval were 0.880 (0.580-0.987). (3) During one-lung ventilation 11 patients responded to the 6 % HES loading dose. SVV correlated with CI ( - 0.668 , P 〈 0.05). The volume expansion efficacy was determined by SVV 9.5 % ( sensitivity = 77 %, specificity = 63 % ). The area under the curve for SVV and 95% confidance interval were 0.971 (0.917-1.024). Conclusion One-lung ventilation does not alter the ability of SVV in monitoring blood volume in patients undergoing thoracoscopy operation.
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 2010年第9期1133-1135,共3页 Chinese Journal of Anesthesiology
关键词 每搏输出量 血管容量 呼吸 人工 Stroke volume Vascular capacitance Respiration, artifical
  • 相关文献

参考文献9

  • 1Berkenstadt H,Margalit N,Hadani M,et al.Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery.Anesth Analg,2001,92(4):984-989.
  • 2Marx G,Cope T,McCrossan L,et al.Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis.Eur J Anaesthesiol,2004,21 (2):132-138.
  • 3Cannesson M,Musard H,Desebbe O,et al.The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients.Anesth Analg,2009.108(2):513-517.
  • 4李成,王月兰,张延红,宋秀梅,刘洋,毕严斌,孙传玉.每搏输出量变异度监测不同潮气量通气时全麻患者血容量变化的准确性[J].中华麻醉学杂志,2009,29(3):246-249. 被引量:4
  • 5Biais M,Bernard O,Ha JC,et al.Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery.Br J Anaesth,2010,104(4):407-413.
  • 6Vieillard-Baron A,Chergui K,Rabiller A,et al.Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients.Intensive Care Med,2004,30(9):1734-1739.
  • 7Mayer J,Boldt J,Poland R,et al.Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo:a review and meta-analysis.J Cardiothorac Vasc Anesth,2009,3 (23):401-406.
  • 8Pinsky MR.Functional hemodynamic monitoring.Intensive Care Med,2002,28 (4):386-388.
  • 9Hanley JA,McNeil BJ.The meaning and use of the area under a receiver operating characteristic (ROC) curve.Radiology,1982,143(1):29-36.

二级参考文献6

  • 1Tousignant CP, Walsh F, Mazer CD. The use of transesophageal echocardiography for preload assessment in critically ill patients. Anesth Analg, 2000, 90: 351-355.
  • 2Bendjelid K, Romand JA. Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care. Intensive Care Med, 2003, 29:352-360.
  • 3Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest, 2002, 121: 2000-2008.
  • 4Reuter DA, Bayerlein J, Goepfert MS, et al. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med, 2003, 29 : 476-480.
  • 5Hofer CK, Muller SM, Furrer L, et al. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off- pump coronary artery bypass grafting. Chest, 2005, 128: 848-854.
  • 6Hanley JA, McNeil BJ. The meaning of use of the area under a receiver operating characteris-tic(ROC) curve. Radiology, 1982, 143 : 29-36.

共引文献3

同被引文献111

  • 1俞建峰,顾勤,刘宁.不同呼吸末正压对机械通气患者心脏前负荷影响及前负荷预测性指标研究[J].中国血液流变学杂志,2008,18(2):237-239. 被引量:12
  • 2刘松桥,邱海波,杨毅,陈永铭,李家琼,沈菊芳.每搏输出量变异度和胸腔内血容量指数对失血性休克犬容量状态的评价[J].中华外科杂志,2006,44(17):1216-1219. 被引量:27
  • 3Wet MB. Dry or something else? Br J Anaesth, 2006,97 (6) : 755-757.
  • 4Rhodes A,Grounds RM. New technologies for measuring cardiac output: the future? Curr Opin Crit Care, 2005,11 (3) : 224-226.
  • 5Bundgaard-Nielsen M, Holte K, Secher NH, et al. Monitoring of peri-operative fluid administration by individualized goal-directed therapy.Acta Anaesthesiol Stand, 2007,51 ( 3 ) : 331-340.
  • 6Rodig G,Prasser C,Keyl C,et al. Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients. Br J Anaesth, 1999,82(4) :525-530.
  • 7Godje O,Hoke K, Goetz AE,et al. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamie instability. Crit Care Med,2002,30 ( 1 ) :52-58.
  • 8Pittman J, Bar-Yosef S, SumPing J, et al.Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement. Crit Care Med, 2005,33(9) :2015-2021.
  • 9Langewouters GJ,Wesseling KH,Goedhard WJ. The pressure dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five component model. J Biomech, 1985,18(8) :613-620.
  • 10Funk DJ,Moretti EW,Gan TJ. Minimally invasive cardiac output monitoring in the perioperative setting. Anesth Analg,2009,108 (3) :887-897.

引证文献14

二级引证文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部