期刊文献+

空调房间温湿度控制模拟分析 被引量:2

Simulated Analysis of Temperature and Moisture Control in Air Conditioning Room
原文传递
导出
摘要 控制空调房间的设定温、湿度且使能耗最少是研究者关注的重要问题。文中以某一空调房间的变水量自动控制为例,分析了变水量空调系统的动态特性,研究了水流量变化、加湿量变化对房间温湿度的影响,分析模拟了PI控制参数的选取对控制过程影响进行。模拟结果显示合理的控制参数能实现较好的控制精度。 The control of temperature and moisture in an air conditioning room with less energy consumption has been paid attention by researchers.Reasonable control parameters' selection can not only control temperature and humidity in high precision,but also save energy.In this paper,the dynamic behavior of variable water volume(vwv) air conditioning system was analyzed.Effects of water flow rate and humidified rate on the room's temperature and moisture were studied.The selection of the parameters for a PI control system was simulated.The results showed that the reasonable control parameters can increase the control precision.
作者 焦一玭
出处 《能源研究与利用》 2010年第6期6-10,共5页 Energy Research & Utilization
关键词 温湿度 PI调节 空调系统 动态特性 temperature and moisture PI control air conditioning system dynamic behavior
  • 相关文献

参考文献7

  • 1Bourhan Tashtoush,Molhim M,M AI Rousan.Dynamic Model of An HVAC System for Control Analysis[J].Energy.2005,(30):1729-1745.
  • 2戴斌文,狄洪发,江亿.变风量空调系统风机总风量控制方法[J].暖通空调,1999,29(3):1-6. 被引量:74
  • 3Thomas B,Mohsen Sdeimani-Mohseni,Per Falden.Feedforward in Temperature Control of Buildings[J].Fuel and Energy Abstracts,2006,(47):114.
  • 4梁春生,智勇.中央空调变流量控制节能方案[M].北京:电子工业出版社,2005
  • 5王正林,王胜开,陈国顺.Matlah/simulink与控制系统仿真[M].北京:电子工业出版社,2000.
  • 6赵荣义 范存养.空气调节[M].北京:中国建筑工业出版社,2002..
  • 7夏德铃,翁贻方,自动控制理论[M].北京:机械工业出版社.2004.

二级参考文献3

  • 1戴斌文.变风量空调系统控制方法研究:(硕士学位论文)[M].北京:清华大学,1998..
  • 2戴斌文,硕士学位论文,1998年
  • 3周谟仁,流体力学泵与风机(第3版),1994年

共引文献84

同被引文献10

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部