摘要
采用正己烷作萃取溶剂提取并富集水样中有机氯农药(OCP),所得提取液经浓缩并定容为1.0mL后,用气相色谱法-电子捕获检测器测定22种有机氯农药。采用Rtx-CLPⅡ和Rtx-1701双柱法根据与标准物质的保留时间相比较进行定性;采用Rtx-CLPⅡ柱对被测组分按外标法进行定量。结果表明:各种农药质量浓度在1~80μg·L^(-1)范围内与峰面积呈线性关系。22种有机氯农药的方法检出限(3S/N)在1.5~5.6ng·L^(-1)之间。用标准加入法测得其回收率在73.3%~107.9%之间,相对标准偏差(n=7)在2.9%~14.8%之间。
Gas chromatography with electron capture detector was applied to simultaneous determination of 22 organochlorine pesticides(OCP's) in water.OCP's was separated and enriched from the water sample by extraction with n-hexane.The extract was concentrated and diluted to 1.0 mL with n-hexane.The double capillary chromatographic column practice,i.e.use of 2 columns of different polarity(the Rtx-CLPⅡcolumn and the Rtx- 1701 column) was adopted for identification of the OCP's by comparing values of t_R with reference materials,and quantification of the OCP's was performed by using the Rtx-CLPⅡcolumn with external standard method.Linear relationships between values of peak area and mass concentration of the 22 OCP's were found same in the range of 1-80μg·L^(-1),with detection limits(3s/k) in the range of 1.5-5.6μg·L^(-1).Recovery of the method was tested,giving values of average recovery ranged from 73.3%to 107.9%and RSD's(n=7) ranged from 2.9%to 14.8%.
出处
《理化检验(化学分册)》
CAS
CSCD
北大核心
2010年第12期1453-1455,1464,共4页
Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词
气相色谱法
液-液萃取
有机氯
水
Gas chromatography
Liquid-liquid extraction
Organochlorine pesticides
Water