期刊文献+

高效液相色谱法测定废水中的全氟辛酸含量 被引量:3

Using HPLC to Determine the Purity of PFOA in the Waste Water
下载PDF
导出
摘要 研究了高效液相色谱法检测工业废水中全氟辛酸含量的分析方法。采用kromasil(250 mm×4.6 mm×5μm)ODS C-18色谱柱,以乙腈与水的体积比50:50、加高氯酸(HClO4,质量分数1%)、三乙胺调pH=3.0为流动相,在该条件下可使试样中各组分完全分离,全氟辛酸的质量浓度在0.05~5 mg/L内线性良好(R=0.999 7、n=7、相对标准偏差1.60%),回收率在95.92%~105.2%。方法准确、快速、简便,可用于工业废水中全氟辛酸的检测。 An analytic method with HPLC is found to test perfluorooctanoic content in industrial wastewater with kromasil (250 mm×4.6 mm×5 μm) ODS C-18 chromatography column and mobile phase of methanol-acetonitrile (50:50/v pH=3 ) adding triethylamine toadjust pH, In this condition ,the components of perfluorooctanoic can be completely separated and a good linear relationship will beachieved to 0.05~5 mg/L(R=0.9997、n=7、RSD=1.60%) ,Recovery is about 95.92%~105.2%. The method was simple, rapid, accurate,which can be used to triethylamine detection in industrial wastewater.
出处 《化工生产与技术》 CAS 2010年第6期47-48,61,共3页 Chemical Production and Technology
关键词 全氟辛酸 高效液相色谱法 外标法 PFOA HPLC external standard method
  • 相关文献

参考文献6

二级参考文献44

共引文献70

同被引文献77

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部