摘要
建立了分离反式油酸(C18∶1)、亚油酸(C18∶2)、亚麻酸(C18∶3)的银离子固相萃取-气相色谱(Ag+-SPE/GC)方法,并应用于乳脂肪中反式脂肪酸的检测。采用自制的银离子固相萃取柱对样品进行预分离,总脂肪酸甲酯化后上样,依次经9mL甲苯-正己烷(体积比5∶95)、8mL甲苯-正己烷(体积比17∶83)、6mL甲苯-乙酸乙酯(体积比17∶83)、10mL甲苯-乙酸乙酯(体积比30∶70)洗脱并分别收集洗脱液,采用气相色谱分别进行检测。结果显示,除了反式亚麻酸的回收率为69.9%~101.0%、相对标准偏差(RSD)为11.0%~18.1%外,其余的反式脂肪酸的回收率均为88.4%~107.2%、RSD为1.2%~11.9%。该方法通过特异性固相萃取的方法对样品进行前处理,较好地避免了样品中顺式及饱和脂肪酸对反式脂肪酸检测的干扰。
A method for the determination of trans fatty acids C18∶1,C18∶2 and C18∶3 in milk fat was developed by silver ion solid phase extraction-gas chromatography(Ag+-SPE/GC).The fatty acid methyl esters derived from total milk fat were loaded onto an Ag+-SPE cartridge,and then eluted with 9 mL of toluene-hexane(5∶95,v/v),8 mL of toluene-hexane(17∶83,v/v),6 mL of toluene-ethyl acetate(17∶83,v/v) and 10 mL of toluene-ethyl acetate(30∶70,v/v) in sequence.The fraction from each step was analyzed by GC.The average recoveries of trans fatty acids ranged from 88.4% to 107.2% with the relative standard deviations(RSDs) from 1.2% to 11.9% except trans linolenic acid with the recoveries from 69.9% to 101.0% and the RSDs from 11.0% to 18.1%.Comparing with the traditional methods,the developed approach can avoid the interference of cis and saturated fatty acids.The method was successfully applied to analyze dairy products.Satisfactory results were shown.
出处
《色谱》
CAS
CSCD
北大核心
2010年第12期1168-1172,共5页
Chinese Journal of Chromatography
关键词
银离子固相萃取
气相色谱法
反式脂肪酸
乳脂肪
silver-ion solid phase extraction(Ag+-SPE)
gas chromatography(GC)
trans fatty acids
milk fat