摘要 以地源热泵垂直埋管换热器为研究对象,建立地源热泵垂直埋管换热器的三维数值模型,通过实验对数值模型进行验证。利用已建的数值模型分析了埋管内水流流速,水温以及钻孔内不同埋管和回填材料对地埋管换热器性能的影响。研究结果表明:地埋管换热器的单位延米换热量随着回填材料导热系数,管内流速,进口水温,埋管的导热系数的增加而增大;埋管管壁的平均温度随着管内流速,进口水温,埋管的导热系数的增加而增大,但随着回填材料导热系数的增加而减小。 The three-dimensional numerical model of the vertical borehole heat exchanger of ground source heat pump was established and the accuracy of numerical model was verified in this paper.The influences of water flow rate and temperature in buried pipe,pipe materials and backfill materials on the performance of vertical borehole heat exchanger were investigated using the numerical model.The results showed that: the heat transfer rate per meter increased as the thermal conductivity of backfill materials and pipe materials,water flow rate in buried pipe and the temperature at the inlet increased.The temperature at the borehole wall has the same change trend with the influence factors except backfill materials,the temperature at the borehole wall decreased as the thermal conductivity of backfill materials increased.
出处 《河南城建学院学报》 CAS 2010年第6期36-39,共4页 Journal of Henan University of Urban Construction
关键词 地源热泵 单位延米换热量 埋管管壁平均温度 数值模拟 ground source heat pump heat transfer rate per meter average temperature at the borehole wall numerical simulation
  • 相关文献

参考文献4

二级参考文献19

  • 1Bernier MA.Clesed-loop ground-coupled heat pump systems[J].ASHRAE Journal,2006,9:12~19.
  • 2Kavanangh S.Field tests for ground thermal propertie-metheds and impact on ground-source heat pump design[J].ASHRAE Transactions,2000,106(1):851~855.
  • 3Pahud D,Matthey B.Comparison of the thermal performance of double u-pipe borehole heat exchangers measured in situ[J].Energy and Buildings,2001,33(5):503~507.
  • 4Nikolas Kyriakis,Apestolos Michopoulos,Konstantin Pattas.On the maximum thermal load of ground heat exchangers[J],Energy and Buildings,2006,38(1):25~29.
  • 5Li Xinguo,Chen Yah,Chen Zhihao,et al.Thermal performances of different types of underground heat exchangers[J].Energy and Building,2006,38(5):543~547.
  • 6Nagano K,Katsura T,Takeda S,et al.Thermal characteristics of steal foundation piles as ground heat exchangers[C]//Proceedings of the 8th International Energy Agency Heat Pump Conference,Las Vegas,Nevada,2005.
  • 7Gao Jun,Zhang Xu,Liu Jun,et al.Numerical and experimental assessment of thermal performance of vertical energy piles:an application[J].Applied Energy,2008,85(10):901~910.
  • 8Skouby A.Thermal conductivity testing-proper engineering + thermally enhanced grout=geoexchangn savings[J].The Source,1998,11(6):4~5.
  • 9Eskilson P.Thermal Analysis of Heat Extraction Boreholes[D].Sweden:Lund Institute of Technology,1987.
  • 10Zeng HY,Diao NR,Fang ZH.A finite line-source model for boreholes in geothermal heat exchangers[J].Heat Transfer-Asian Research,2002,31(7):558~567.

共引文献62

同被引文献10

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部