9Miles K A,Hayball M P,Dixon A K.Color perfusion imaging:a newapplication of computed tomography[J].Lancet,1991,337(3):643 ~ 645.
10Hamberg L M,Hunter G J,Halpern E F,et al.Quantitave,high resolustion measurement of cerebralvascular physiology with slipring CT[J].AJNR,1996,17(4):639~ 650.
5Ricci PE,Karis JP,Heiserman JE,et al.Differentiating recurrent tumor from radiation necrosis:time for re-evlauation of positron emission tomography? AJNR,1998,19:407-413.
6Datta NR,Pasricha R,Gambhir S,et al.Postoperative residual tumour imaged by contrast-enhanced computed tomography and 201Tl single photon emission tomography:can they predict progression-free survival in high-grade gliomas? Clin Oncol (R Coll Radiol),2004,16:494-500.
7Kline JL,Noto RB,Glantz M.Single-photon emission CT in the evaluation of recurrent brain tumor in patients treated with gamma knife radiosurgery or conventional radiation therapy.AJNR,1996,17:1681-1686.
8Schwartz RB.Neuroradiology of brain tumors(Review).Neurol Clin,1995,13:723-756.
9Sugahara T,Korogi Y,Tomiguchi S,et al.Posttherapeutic intraaxial brain tumor:the value of perfusion-sensitive contrast-enhanced MR imaging for differentiating tumor recurrence from nonneoplasic contrast-enhancing tissue.AJNR,2000,21:901-909.
10Cenic A,Nabavi DG,Craen RA,et al.A CT method to measure hemodynamics in brain tumors:validation and application of cerebral blood flow maps.AJNR,2000,21:462-470.
4Maruya J, Yamamotn K, Ozawa T, et al. Simultaneous multi-sec tion perfusion CT and CT angiography for the assessment of acute isehemic stroke[J]. Acta Neurochirurgica (Wien), 2005,147 (4) : 383-392.
5Gonzalez R G. Imaging-guided acute ischemic stroke therapy: From"time is brain"to"physiology is brain" [J]. AJNR, 2006,27 (4) :728-735.
6Miles K A,London N J M,Lavelle J M,et al. CT staging of renal carcinoma:a prospective comparison of three dynamic computed tomography techniques[J]. Eur J Radiol, 1991, 13(7) :37-42.
7Miles K A, Griffiths M R. Perfusion C T: a worthwhile enhance- ment [J]. Br J Radio1,2003,76(904) :220-231.
8Lin K, Do K G, Ong P, et al. Perfusion CT improves diagnostic accuracy for hyper acute ischemie stroke in the 3-hour window= study of 100 patients with diffusion MRI confirmation[J]. Cere brovase Dis,2009,28(1) :72-79.
9Kane I, Hand P J, Rivers C, et al. A practical assessment of magnetic resonance diffusion-perfusion mismatch in acute stroke: observer variation and outeome[J]. Journal of Neurology,2009, 256(11) :1832-1838.
10Murphy B D, Chen X, Lee T Y. Serial changes in CT cerebral blood volume and flow after 4 hours of middle cerebral occlusion in an animal model of embolJc cerebral ischemic[J]. AJNR, 2007,28(4) :743-749.