摘要
介绍了压力传感器,灭弧室内产气材料的选择,排气通道和外壳的优化设计及低压断路器灭弧室压力测量的方法,实例介绍压力测量在低压灭弧室优化设计中的应用。
The pressure sensor,pressure measurement method of low voltage circuit breaker arc chamber,selection of aerogenesis material,optimal design of venting path and hull were introduced.The application of pressure measurement in the optimal design for low voltage circuit breaker arc chamber was introduced by a few examples.
出处
《低压电器》
北大核心
2010年第24期8-11,共4页
Low Voltage Apparatus
关键词
压力测量
低压断路器
灭弧室
优化设计
pressure measurement
low voltage circuit breaker
arc chamber
optimal design