摘要
提出了深冷处理过程中的"过冷量"概念,介绍了最佳过冷量的获取方法,为某型号深冷箱建立了冷量控制模型,并设计了基于最佳过冷量控制算法的深冷处理控制系统。该系统的控制输出环节更加合理且能有效提高低温氮气与被处理材料之间的换热效率,大大降低了液氮消耗量,节约了深冷处理工艺成本。
The concept of subcooling capacity in cryogenic treatment was proposed, the method of getting the best subcooling capacity was introduced, the cooling capacity control model of a certain cryogenic container was established. Finally the control system of cryogenic treatment was desined based on the best subcooling capacity control algorithm. The output part of the system is more reasonable and can improve the heat transfer efficiency between the low temperature nitrogen gas and the treated materials effectively, reduce the consumption of liquid nitrogen and the cost of cryogenic treatment process.
出处
《低温工程》
CAS
CSCD
北大核心
2010年第6期25-28,共4页
Cryogenics
基金
山西省科技攻关项目(2007031153)
太原市大学生科技创新项目(100115160)
中国科学院"低温工程学"重点实验室开放课题基金(YOAS012105)
关键词
冷量控制
深冷处理
过冷量
最佳过冷量
换热效率
cooling capacity control
cryogenic treatment
subcooling capacity
best subcooling capacity
heat transfer efficiency