期刊文献+

空气中二异丁基甲酮气相色谱应急快速检测方法研究

Establishment of emergent rapid gas chromatographic detection of diisobutyl ketone in workplace air
原文传递
导出
摘要 目的建立应急快速检测空气中二异丁基甲酮气相色谱测定方法。方法按照GBZ/T210.4—2008《职业卫生标准制定指南》的要求进行实验。结果本方法在0~1 600μg/m l范围呈线性关系;样品在注射器中可保存5 h;方法的重现性好,不同浓度的相对标准偏差为1.00%~1.33%;方法的检出限为0.085μg/m l;空气中可能与二异丁基甲酮共存的环己烷、甲基环己烷、异佛尔酮等在本方法条件下不干扰测定。结论此方法各项指标均达到《职业卫生标准制定指南》的要求,适用于工作场所空气中二异丁基甲酮的现场监测。 Objective To establish a rapid gas chromatographic method of diisobutyl ketone in workplace air for emergent event.Methods This method was studied according to standardization of methods for determination of toxic substances in workplace air.Results This method presents good linear relation within the range of 0—1 600 μg/ml.The sample could be steadily stored in syringe for 5 hours.The precision(RSD)is 1.00%—1.33% and the detection limit is 0.085 μg/ml.Additionally,it will be not interfered by other volatile organic solvents,such as cyclohexanone,methylcyclohexanone,isophorone etc.Conclusion This method meets all the requirements of standardization of methods for determination of toxic substances in workplace air,therefore it should be feasible for the rapid determination of diisobutyl ketone in workplace air.
出处 《中国工业医学杂志》 CAS 北大核心 2010年第6期421-422,441,共3页 Chinese Journal of Industrial Medicine
基金 广东省深圳市科技局科研项目(编号:200703245)
关键词 空气 二异丁基甲酮 气相色谱 air diisobutyl ketone gas chromatograph
  • 相关文献

参考文献3

  • 1GBZ2-2002.工作场所有害因素职业接触限值[S].[S].,..
  • 2NIOSH Manual of Analytical Methods ( NMAM ) [ Z ]. Fourth Edition. KETONESI: METHOD 1300, Issue 2, dated 15 August 1994.
  • 3GBZ/T210.4-2008,职业卫生标准制定指南第四部分工作场所空气中化学物质测定方法[S].

共引文献187

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部