期刊文献+

采用金阴极的光子计数成像探测器的性能 被引量:9

Properties of Photon Counting Imaging Detector with Au Photocathode
原文传递
导出
摘要 采用Au作为感应读出式光子计数成像探测器的光阴极,在分辨率测试板上蒸镀了薄膜厚度为15nm的Au作为透射式阴极。实验测试了加Au阴极后微通道板(MCP)的增益性能,探测器的分辨率和计数率等成像性能,与未加Au阴极时相应的系统性能做了对比。结果表明,加Au阴极后MCP的脉冲高度分布呈准高斯型,随着MCP工作电压的提高,脉冲高度分布曲线的峰值向高增益方向移动,曲线的半峰全宽(FWHM)逐渐变宽;Au阴极有效提高了光子计数成像探测器的探测效率和信噪比;分辨率测试结果表明加Au阴极后探测器的空间分辨率优于75μm,随着计数率的提高分辨率将会下降,在保证系统分辨率优于150μm时计数率可达到13.5kHz。 Au photocathode is used in photon counting imaging system with induction readout.A 15 nm gold film is deposited on the resolution test board and it is used for transmission photocathode.The gain performance of micro-channel plates(MCP),resolution and counting rate of the detector with Au photocathode are tested.The results show that the system with Au cathode has a quasi-Gaussian pulse height distribution(PHD) curves.The peak of the PHD curves moved to the high-gain zone and the full width at half maximum(FWHM) gradually widened as the voltage increased.After the adoption of Au cathode,the detection efficiency and the signal-to-noise ratio of photon counting imaging detector effectively improved.The resolution test results show that the spatial resolution of the detector is better than 75 μm,and the counting rate can reach 13.5 kHz when the system′s resolution is better than 150 μm.
出处 《光学学报》 EI CAS CSCD 北大核心 2011年第1期217-222,共6页 Acta Optica Sinica
基金 国家自然科学基金(10878005)资助课题
关键词 光学器件 探测器 光子计数成像 微通道板 Au阴极 电荷感应 optical devices detectors photon counting imaging micro-channel plate(MCP) Au cathode charge induction
  • 相关文献

参考文献17

  • 1张兴华,赵宝升,缪震华,朱香平,刘永安,邹玮.紫外单光子成像系统的研究[J].物理学报,2008,57(7):4238-4243. 被引量:25
  • 2刘永安,赵宝升,朱香平,缪震华,张兴华,邹玮.楔条形阳极探测器的性能测试与分析[J].光子学报,2009,38(4):750-755. 被引量:6
  • 3朱香平,赵宝升,刘永安,缪震华,张兴华,邹玮.30.4nm极紫外成像探测器的实验研究[J].光学学报,2008,28(10):1925-1929. 被引量:14
  • 4Zhang X. H. Zhao B. S. Zhao F. F. et al.. An ultraviolet photon counting imaging detector system based on Ge induction readout mode[J].Nucl.Instrum. Meth.A, 2009, 610(9): 724-727.
  • 5Lapington J. S., Chakrabarti S., Cookt T. et al.. A position sensitive detector for SPIDR-a mission to map the cosmic web[J].Nucl.Instrum. Meth. A, 2003, 513(1-2): 159-162.
  • 6Barnstedt J., Grewing M.. Development and characterization of a visible light photon counting imaging detector system [J].Nucl. Instrum. Meth. A, 2002, 477(1-3): 268-272.
  • 7Ren X.G., Ning C.G., Deng J.K. et al.. (e,2e) electron momentum spectrometer with high sensitivity and high resolution[J].Rev. Sci. Instrum., 2005, 76(6): 063103-1-063103-8.
  • 8曹根瑞,俞信,胡新奇.光子计数成像技术及其应用[J].光学学报,1996,16(2):167-172. 被引量:3
  • 9Jagutzki O. Barnstedt J. Spillmann U. et al.. Fast position and time sensitive read-out of image intensifiers for single photon detection[C]. SPIE, 1999, 3764: 61-69.
  • 10Lapington J. S. Sanderson B. Microchannel plate limited resolution with the Vernier anode[C]. SPIE, 2000, 4139: 242-249.

二级参考文献38

共引文献50

同被引文献97

引证文献9

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部