期刊文献+

考虑补偿方法的单相DVR检测方法研究与仿真 被引量:2

Research and Simulation of Detection of Single-Phase DVR Based on Compensation Methods
下载PDF
导出
摘要 定量分析计算电网电压暂降时DVR逆变单元与电网的功率交换情况,详细研究逆变单元在各种补偿策略下的输出电压和有功功率与故障前后电网电压、负载电压和参考相量的具体关系,并根据具体关系总结出5种补偿方法,通过Matlab平台对各种补偿方法进行仿真研究,最后根据不同的补偿方式进行单相DVR检测方法研究。 This paper quantitatively analyzed and calculated the power exchange between DVR inverter unit and grid with voltage sagged, focusing on the specific relationships among the output voltage, active power of the inverter module under different compensation strategies and grid voltage, load voltage and reference phase before and after the fault, and summarized five kinds of compensation methods. Simulation of these compensation methods were conducted through the Matlab platform, and finally were studied based on different means of single-phase DVR detection.
出处 《电网与清洁能源》 2011年第1期35-38,共4页 Power System and Clean Energy
关键词 动态电压恢复器 补偿方法 检测方法 电力电子 dynamic voltage restorer compensation methods detection method power electronics
  • 相关文献

参考文献5

二级参考文献22

  • 1杨晓萍,许辉,吴成林.动态电压恢复器电压补偿策略及其仿真研究[J].电工技术杂志,2004,26(9):58-61. 被引量:10
  • 2张庆超,肖玉龙.一种改进的电压暂降检测方法[J].电工技术学报,2006,21(2):123-126. 被引量:61
  • 3KAURA V., BLASKO V. Operation of a phase Locked Loop System Under Distorted Utility Conditions[J].IEEE Transactions On Industry Applications. 1997, Vol. 33(1), pp58-63.
  • 4ZHAN ChangJiang, FITZER C. Software phase-Locked loop applied to Dynamic Voltage Restorer[C]. IEEE Proceedings of PES Winter Meeting. 2001.PP1033-1038.
  • 5MOSTAFA M.A, CAIRO A. Kalman Filtering Algorithm For Electric Power Quality Analysis: Harmonics And Voltage sags Problems. IEEE 2003,110-119.
  • 6MEHRA R.K. On the Identification of Variances and Adaptive Kalman Filtering [J]. IEEE Transactions on automatic control.1997, Vol. Ac-15 (2). PP.175-184.
  • 7VIATHGAMUWA D.M, PERERA A.D.R, CHOI S.S. Voltage Sag Compensation With Energy Optimized Dynamic Voltage Restorer[J]. IEEE Transaction on Power Delivery,EF.2003.Vol. 18(3)PP.928-936.
  • 8Woodley N H, Morgan L, Sundaram A. Experience with an Inverter-based Dynamic Voltage Restorer. IEEE Transactions on Power Delivery,1999, 14(3):1181~1186
  • 9Campbell A, McHattie R. Backfilling the Sinewave--A Dynamic Voltage Restorer Case Study. Power Engineering Journal, 1999, 13(3):153~158
  • 10Wunderlin T, Dahler P, Amhof D, et al. Power Supply Quality Improvement with a Dynamic Voltage Restorer (DVR). In:Proceedings of the International Conference on Energy Management and Power Delivery, EMPD Proceedings of the 1998 2nd International Conference on Energy Management and Power Delivery (EMPD'98). Singapore:1998. 518~525