摘要
使用带铁氧体的罗可夫斯基线圈在交流电压下检测SF6气体及SF6/N2混合气体的同轴电极系统中导电微粒的起始局部放电。当线圈的响应频率为100kHz时,检测系统具有较高的灵敏度,这个系统检测灵敏度为 2~10 PC。现介绍已取得一些检测结果或结论。
Under AC voltage, initial partial discharge of conducting particles in the coaxial electrode system of SF6 gas and SF6/N2 mixed gas are inspected using Rokovski Coil with ferrite, As response frequency of the coil is 100 kHz, the inspection system has high sensitivity.
出处
《冶金动力》
1999年第5期16-19,共4页
Metallurgical Power