摘要
采用接触氧化法与高效垂直流人工湿地相结合处理城市生活污水,武夷山市污水处理厂经过2a多的运行,结果表明,该工艺对COD、BOD、SS、TN和TP的去除率分别达到86%、90%、76%、69%和51%,出水水质指标优于《城镇污水处理厂污染物排放标准》(GB18918-2002)的一级B标准,该工艺采用前置接触氧化法,具有占地少、处理效率高和运行管理简单等特点。为提高工程处理效率、完善工程运行管理,二期工程设计对一期工程存在的缺陷和不足进行改进,力求达到最佳效果。
The contact oxidation method combining to high efficient vertical flow constructed wetland has been applied to treat urban domestic sewage in Wuyishan wastewater treatment plant for more than 2 years. The results show that the process has high removal rate of COD (86%) , BOD (90%) , SS (76%) , TN (69%) and TP (51% ). The water quality after treatment can reach B of the first class standard of " Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant" (GB18918 -2002). The process occupied small land with high treatment efficiency and easy management. The second period project design will improve the shortcomings of the first project to realize the optimum results.
出处
《环境科学导刊》
2011年第1期69-71,78,共4页
Environmental Science Survey
关键词
接触氧化
污水
人工湿地
运行管理
contact oxidation
sewage
constructed wetland
operation and management