摘要
对抗燃油在运行中可能发生的变化进行分析。分析表明,某电厂1号、2号机组抗燃油电阻率、泡沫特性、空气释放值均已超标。使用抗燃油专用再生吸附滤油机对该厂抗燃油进行在线处理后,抗燃油体积电阻率超标的问题得以解决。
The quality rariation of fire-resistant oil may occurred in operation has been analysed,result of analysis shows that the resistivity,the foaming behavior,and the air-releasing value of fire-resistant oil used for units no.1 and no.2 in one power plant all have exceeded the set standard,after on-line treatment of the fire-resistant oil in said power plant by using a special oil-filtering machine for regeneration-adsorption of the fire-resistant oil,the problem of volume resisitivity exceeding set standard for the fire-resistant oil has been resolved.
出处
《热力发电》
CAS
北大核心
2011年第1期76-78,共3页
Thermal Power Generation
关键词
抗燃油
体积电阻率
吸附
滤油机
fired-resistant oil
volume resistivity
adsorption
oil-filtering machine