期刊文献+

SUPER304H锅炉钢管局部腐蚀分析及其防护对策 被引量:2

ANALYSIS OF LOCALIZED CORROSION ON SUPER304H STEEL TUBES USED FOR BOILERS AND PREVENTIVE COUNTERMEASURES THEREOF
下载PDF
导出
摘要 对某沿海在建机组锅炉用SUPER304H钢管出现的局部腐蚀进行了宏观形貌、化学成分、金相、扫描电镜及能谱分析结果表明,SUPER304H钢管局部腐蚀的主要原因是由氯离子引起的。对此,建议在SUPER304H钢管海运及存放时,加盖帆布和采用缓蚀剂进行防护。对已产生局部腐蚀的管材进行打磨,并经渗透探伤和壁厚测量检验合格后可正常使用。 The localized corrosion occurred on SUPER304H steel tubes used for boilers of units under construction in coastal areas has been analysed by using macroscopic examination,chemical composition test,metallographic detection,scanning electron microscope,and energy spectrum.Results show that the main cause leading to localized corrosion on SUPER304H steel tubes is due to chlorine ions.For this,it is recommended that the said steel tubes should be covered with canvas during sea transportation and storage,and being protected with corroson inhibitors.The tube materials,which are already being corroded,should be rubbed,and examined through liquid penetration test and wall thickness measurement,after reaching acceptable level of quality,just then they can be normally used.
出处 《热力发电》 CAS 北大核心 2011年第1期87-90,共4页 Thermal Power Generation
关键词 锅炉 SUPER304H钢管 局部腐蚀 氯离子 孔蚀 ultra-supercritical unit boiler SUPER304H steel tube localized corrosion chlorine ion pitting corrosion
  • 相关文献

参考文献1

  • 1杨华春.日本SUPER304H奥氏体不锈钢锅炉管评述[A].超超临界锅炉用钢及焊接技术协作网论文集[C].2005:231-241.

同被引文献20

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部