摘要
介绍了米顿罗液压隔膜计量泵的工作原理,分析了隔膜泵在运行中出力不足的原因,提出了相应的解决办法。供隔膜计量泵的日常维护和故障抢修时参考。
The working principle of the Milton Roy hydraulic membrane metering pump was introduced.The reason of the output deficiency of the membrane pump in operation was analyzed,and relevant solving method was put forward,which can be used as reference for daily maintenance and troubleshooting of the membrane metering pump.
出处
《华电技术》
CAS
2011年第1期48-49,52,共3页
HUADIAN TECHNOLOGY
关键词
米顿罗计量泵
液压隔膜计量泵
缺陷
原因
Milton Roymetering pump
hydraulic membrane metering pump
defect
reason