摘要
在自行火炮靶场定型试验中,湿热环境试验被习惯性地选为[35℃,95%RH,48 h恒定]的试验条件提出了不同看法,从湿热环境模拟试验机理、对试验标准的理解和火炮湿热环境一般性效应等几方面进行了分析,提出了应采用GJB 150A或美军标810F推荐的"加速的交变的试验条件"来考核自行火炮环境适应性的观点。
In qualification test of self-prolled artillery,the test condition of damp heat test was defined as 35 ℃,95% RH,48 h,constant.A different viewpoint was put forward based on analysis of damp heat test mechanism,comprehension on test critcia,and general effect of damp heat environment on artillery.The viewpoint was introduced that the accelerating and alternating test conditon recommended by GJB 150A or MIL-STD-810F should be applied to examine environmental worthiness of artillery.
出处
《装备环境工程》
CAS
2011年第1期66-69,共4页
Equipment Environmental Engineering
关键词
自行火炮
环境试验
湿热试验
self-propelled artillery
environmental test
damp heat test