摘要 人工晶状体植入后若发生倾斜和(或)偏中心,患者可出现眩光、视力下降等症状,测量和计算人工晶状体植入后的倾斜和偏中心,对于人工晶状体和手术方案的选择具有指导意义。目前可以通过超声波、超声生物显微镜、光学相干断层扫描、Pentacam三维眼前段分析仪等观测人工晶状体的倾斜和偏中心,但其各有利弊,有望通过建立描述人工晶状体的几何数学模型,精确计算其实际倾斜和偏中心数值。
出处 《国际眼科纵览》 2010年第6期389-392,共4页 International Review of Ophthalmology
  • 相关文献

参考文献22

  • 1Koivula A,Petrelius A,Zetterstr(o)m C.Clinical outcomes of phakic refractive lens in my opic and hyperopic eyes:1-year results.J Cataract Refract Surg,2005,31:1145-1152.
  • 2Matthews MW,Eggleston HC,Hilmas GE.Development of a repeatedly adjustable intraocular lens.J Cataract Refract Surg,2003,29:2204-2210.
  • 3Jacobi PC,Dietlein TS,Lüke C,et al.Multifocal intraocular lens implantation in prepresbyopic patients with unilateral cataract.Ophthalmology,2002,109:680-686.
  • 4Montés-Micó R,Ferrer-Blasco T,Cervi(n)o A.Analysis of the possible benefits of aspheric intraocular lenses:review of the literature.J Cataract Refract Surg,2009,35:172-181.
  • 5Zhang Q,Jin W,Wang Q.Repeatability,reproducibility,and agreement of central anterior chamber depth measurements in pseudophakic and phakic eyes:optical coherence tomography versus ultrasound biomicroscopy.J Cataract Refract Surg,2010,36:941-946.
  • 6Pavlin CJ,Sherar MD,Foster FS.Subsurface ultrasound biomicroscope imaging of the intact eye.Ophthalmology,1990,97:224-250.
  • 7Loya N,Lichter H,Barash D,et al.Posterior chamber intraocular lens implantation after capsular tear:ultrasound biomicroscopy evaluation.J Cataract Refract Surg,2001,27:1423-1427.
  • 8Grewal DS,Brar GS,Grewal SP.Assessment of central corneal thickness in normal,keratoconus,and post-laser in situ keratomileusis eyes using Scheimpflug imaging,spectral domain optical coherence tomography,and ultrasound pachymetry.J Cataract Refract Surg,2010,36:954-964.
  • 9Doors M,Berendschot TT,de Brabander J,et al.Value of optical coherence tomography for anterior segment surgery.J Cataract Refract Surg,2010,36:1213-1229.
  • 10Ba(i)koff G.Anterior segment OCT and phakic intraocular lenses:a perspective.J Cataract Refract Surg,2006,32:1827-1835.

二级参考文献8

  • 1Kanski JJ.Closed intraocular microsurgery in ocular trauma.Trans Ophthalmol Soc UK 1978;98:51-54
  • 2Korynta J,Bok J,Cendelin J,MiChalova K.Compiter modeling of visual impaimlent caused by intraocular lens misalignment.J Cataract Refract Surg 1999;25:100-105.
  • 3Oshika T, Sugita G, Miyata K,et al.Influence of tilt and decentration of scleral T ,sutured inttraocular lens on ocular higher-order wavefront aherration.Br J Ophthalmo 1.2006[Epub ahead of print].
  • 4Sasaki K,Sakamotoy, Shibam T, Nakaizumi H,Emori Y. Measurement of postoperative intraocular lens tilting and decentration using Scheimpflug images,Cataract Refract Surg 1989; 15:454-457.
  • 5Bauraeisterm,Neidhardt B,Strobel J,et al.Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic intraocular lenses with 6-ram optics in an intraindividual comparison. Am J Ophthalmol 2005; 140:1051-1058.
  • 6Solomon K,Gussler JR,Gussler C,Van Meter WS.InCidence and management of complications of transsclerally sutured posterior chamber lenses. J Cataract Refract Surg. 1993; 19:488-93
  • 7陆斌,沈泽民.后房型人工晶体倾斜和偏心的活体测量及研究[J].中华眼科杂志,1999,35(1):40-42. 被引量:17
  • 8邹玉平,林振德,李绍珍.四点式人工晶体缝线固定术的初步疗效观察[J].中国实用眼科杂志,2001,19(3):197-198. 被引量:16

共引文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部