期刊文献+

BLADE技术在3.0T磁共振克服关节扫描中运动伪影上的临床应用 被引量:8

Clinical Application of 3.0T MRI BLADE Technique in Correcting Joint Motion Artifacts
原文传递
导出
摘要 目的:探讨在3.0T磁共振成像过程中,刀锋伪影较正(BLADE)技术在克服关节扫描中运动伪影方面的的的临床应用。方法:20例行四肢关节MR扫描检查的患者(肩关节10例,腕关节10例),在常规行T2WI常规扫描中出现不同程度的运动伪影,然后引入BLADE技术,扫描T2WI.,以能否清晰显示韧带肌腱而无重影为标准,对比常规序列扫描来评价BLADE技术在消除关节扫描过程中图像运动伪影方面的价值。结果:常规T2扫描出现运动伪影,用BLADE技术序列扫描出来的图像运动伪影消失,对比度明显提高。结论:应用BLADE技术进行扫描可以有效消除病人细微运动造成的运动伪影,获得高分辨率无伪影具有临床诊断价值的理想的图像。 Objective:To evaluate the clinical applications of BLADE techniques in correcting joint motion artifacts.Methods:20cases who were found joint motion artifacts with routine MRI examination were performed BLADE sequence scanning(10case of shoulder,the other 10case of wrist).As the standard of clearly showing the ligament of the tendon without ghosting,compared with rou-tine joint MRI examination sequence,the effects of BLADE technique were evaluated.Results:The joint motion artifacts exist in routine MR T2 scanning And it disappeared in the image of T2WI BLADE sequence.The using of BLADE techniques played an important role in correcting motion artifacts in MRI scanning.Conclusion:The application of BLADE Technique helps to correct joint motion artifacts and It can be used to high image quality.Intracranial pathology is equally or better demonstrated with BLADE.
出处 《现代生物医学进展》 CAS 2010年第23期4547-4549,共3页 Progress in Modern Biomedicine
关键词 关节 BLADE技术 MRI 运动伪影 Joint 3.0Megnatic Resonance Imaging BLADE Artifact
  • 相关文献

参考文献8

  • 1秦文,于春水,李坤成.螺旋桨(PROPELLER)技术的原理及应用[J].医学影像学杂志,2005,15(10):912-915. 被引量:24
  • 2Pipe JG, Farthing VG, Forbes KP. Multishot Diffusion-weighted FSE Using PROPEIIER MRI[J].Magn Reson Med, 2002,47(1):42-52.
  • 3Glover GH, Pauly JM. Projection Reconstruction Techniques for Reduction Of Motion Effects in MR/ [J].Magn Reson Med,1992,28 (3):275-289.
  • 4Forbes KP, Pipe JG, Bird CR, et al. PROPELLER MRI:Clinical Test- ing of a Novel Technique for Quantification and Compensation of Head Motion [J]. Magn Resort Med, 2001, 14(3):215-222.
  • 5Pipe JG. Motion Correction with PROPELLER MRI: Application to Head Motion and Free-breathing cardiac Imaging [J]. Magn Reson Med, 1999,42(10): 963-969.
  • 6Forbes KP, Pipe JG, KariS JP, et al. Brain Imaging In the Unsedated Pediatric Patient: Comparison of Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction and Singleshot Fast Spin-echo Sequences[J]. AJNR, 2003,24(8):795-798.
  • 7戈明媚,王秋良,刘志钦,刘晓林,廖玉珍,孙玮,孙楠,张英魁.MR螺旋桨扫描技术在消除伪影方面的临床应用[J].中华放射学杂志,2006,40(2):208-212. 被引量:37
  • 8宋云龙,张挽时,王忠,祝红线,方红,毕永民.BLADE技术消除磁共振成像运动伪影的临床应用[J].放射学实践,2007,22(11):1228-1231. 被引量:23

二级参考文献33

  • 1秦文,于春水,李坤成.螺旋桨(PROPELLER)技术的原理及应用[J].医学影像学杂志,2005,15(10):912-915. 被引量:24
  • 2戈明媚,王秋良,刘志钦,刘晓林,廖玉珍,孙玮,孙楠,张英魁.MR螺旋桨扫描技术在消除伪影方面的临床应用[J].中华放射学杂志,2006,40(2):208-212. 被引量:37
  • 3Nishimura DG,Irarrazabal P,Meyer CH.A velocity k-space analysis of flow effects in echo-planar and spiral imaging.Magn Reson Med,1995,33:549-556.
  • 4Glover GH,Pauly JM.Projection reconstruction techniques for reduction of motion effects in MRI.Magn Reson Med,1992,28:275-289.
  • 5Meyer CH,Hu BS,Nishimura DG,et al.Fast spiral coronary artery imaging.Magn Reson Med,1992,28:202-213.
  • 6Ehman R,Felmlee J.Adaptive technique for high-definition MR imaging of moving structures.Radiology,1989,173:255-263.
  • 7Ordidge RJ,Helpern JA,Qing ZX,et al.Correction of motional artifacts in diffusion-weighted MR images using navigator echoes.Magn Reson Imaging,1994,12:455-460.
  • 8Sachs T,Meyer CH,Irarrazabal P,et al.The diminishing variance algorithm for real-time reduction of motion artifacts in MRI.Magn Reson Med,1995,34:412-422.
  • 9Pipe JG.Motion correction with PROPELLER MRI:application to head motion and free-breathing cardiac imaging.Magn Reson Med,1999,42:963-969.
  • 10俎栋林.磁共振成像学[M].北京:高等教育出版社,2004.101-103,241-243,271-274,507-529.