期刊文献+

高灵敏度QCM在阻尼介质中的分辨率改进

Resolution Improvement of High Sensitivity QCM in Damping Media
下载PDF
导出
摘要 为改进晶体谐振器在阻尼介质中频率的稳定性和分辨率,研究了分辨率和干扰频率的理论关系,采用D触发器设计混频电路来减小回路的噪音干扰,由此分析了石英晶片上附着微小质量和液体时的等效电路,并制作了QCM传感器,得到了电路响应曲线;取4MHz、10MHz的谐振器在液体中进行了试验。结果表明:提高晶体谐振器的分辨率,减小噪音在谐振器中的出现比提高频率更有效。 In order to improve the stability and resolution of crystal oscillator frequency in the damping media,the relationship between frequency resolution and interference was studied.Mixer circuit was designed to reduce the loop noise using D flip-flop.The equivalent circuit of the quartz crystal mass loading and liquid damping was analyzed,QCM sensor was developed,and then response curve was obtained.In the experiment,4,10 MHz resonator was tested in the liquid.The results show that the resolution of improving crystal resonator,reducing the noise in the resonator is more effective than increasing the frequency.
作者 徐晶 骆英
机构地区 江苏大学理学院
出处 《传感技术学报》 CAS CSCD 北大核心 2010年第12期1757-1760,共4页 Chinese Journal of Sensors and Actuators
基金 国家"863"基金项目资助(2009AA03Z107) 国家自然科学基金项目资助(50875114)
关键词 石英晶体微天平 频率响应 灵敏度分析 阻尼 分辨率 quartz crystal microbalances frequency response sensitivity analysis damping resolution
  • 相关文献

参考文献12

  • 1罗洁,曾光明,汤琳,尹娟,黎媛萍.生物传感型核壳纳米颗粒的制备与应用[J].分析化学,2009,37(12):1847-1852. 被引量:1
  • 2陈昕,周康源,顾宇,柯文鸿.压电生物传感器研究进展[J].传感技术学报,2003,16(3):291-298. 被引量:8
  • 3Shen Dazhong,Kang Qi,Du Junguo.New Cut Angle Quartz Crystal Microbalance with Low Frequency Temperature Coefficients in an Aqueous Phase[J].Talanta,2008,76(4):803-808.
  • 4徐晶,骆英.QCM振荡频率检测平台的建立及其稳定性探讨[J].传感技术学报,2008,21(5):791-794. 被引量:12
  • 5刘清君,胡朝颖,叶伟伟,张威,徐莹,王平.微电极阵列细胞阻抗传感器研究[J].传感技术学报,2009,22(4):447-450. 被引量:3
  • 6Zampetti E,Pantalei S.Temperature and Flow Velocity Control for Quartz Crystal Microbalances[C] //Proceedings,IEEE International Symposium on Circuits and Systems,2006:4399-4402.
  • 7Myungsun,Seo Hyejung,Tak Youngjo.Enhanced Mass Sensitivity of ZnO Nanorod Grown Quartz Crystal Microbalances[J].Sensors and Actuators,B:Chemical,2009,135(2):444-448.
  • 8Itoh Atsushi.A Frequency of the Quartz Crystal Microbalance(QCM)that is Not Affected by the Viscosity of a Liquid[J].Measurement Science and Technology,2008,19(7):253-258.
  • 9Allan D W.Statistics of Atomic Frequency Standards[J].Proceedings of the IEEE,1996,54(2):26-28.
  • 10Vig J R,Walls F L.A Review of Sensor Sensitivity and Stability[C] //Proceedings of IEEE/EIA International Frequency Control Symposium and Exhibition,2000:30-33.

二级参考文献65

共引文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部