摘要 本文叙述了吸光度比值-导数光谱新方法的原理,研究了在普通分光光度计上用计算法完成吸光度比值导数运算、同时测定苯酚和间苯二酚含量的实验方法,取得了较为满意的结果。苯酚的回收率为99.4%~104.2%(n=25,RSD=1.1%),间苯二酚的回收率为97.1%~102.8%(n=25,RSD=1.6%)。 In this paper,the principle of a new absorbance ratio derivative method was described.The experimental methods of derivation with subtraction technique on ordinary spectrophotometer and simultaneous determination of phenol and resorcin were studied.The result is satisfying.The recovery of resorcin and phenol is in the range of 99 4% 104 2% ( n=25 ,RSD=1 1%) and 97 1% 102 8%( n=25 ,RSD=1 6%) respectively.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 1999年第4期581-584,共4页 Spectroscopy and Spectral Analysis
关键词 吸光度比值 导数光谱 多组分 苯酚 间苯二酚 New absorbance ratio derivative method, Simultaneous determination, Phenol, Resorcin