摘要
本文用国产微波消解系统,研究了安全地,有效地消化固体类化妆品最佳酸体系,以及消解罐内压力,微波功率和消化时间等参数并研究了固体类化妆品中一些无机元素的分析方法,即溶样后用ICP-AES法测定砷,铅,镉,铬,锶,铋,硒元素的含量。用该法测定化妆品国家一级标样相对误差0.74%。
A safe and effective method for the microwave digestion of solid state cosmetic samples is described.The overall digestion conditions,including pressure,power,acids and time of digestion were evaluated by analysing Pb,As,Cr,Cd,Sr,Bi and Se of routine samples with ICP AES.This method was applied to the determination of certified materials with good agreement.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
1999年第4期598-600,共3页
Spectroscopy and Spectral Analysis