摘要 钨盐涂覆处理石墨管,大幅度提高测定锂的灵敏度。配以(NH4)2SO4基体改进剂,消除生物基体干扰。特征浓度5.53×10-3μg·mL-1/1%,回收率大于93.72%,相对标准偏差小于8.93%。 Using a tungstate coated graphite tube.The sensitivity of Li was significantly increased and trace Li in serum samples was determined by Zeeman graphite AAS with (NH 4) 2SO 4 as a matrix modifier.The effects of different metal ions and biological matrix were eliminated.The characteristic concentration is 5 53×10 -3 μg·mL -1 /1%.The recovery is greater than 93 72 %. The relative standard deviation is less than 8 93 %.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 1999年第4期604-606,共3页 Spectroscopy and Spectral Analysis
关键词 血药浓度 钨涂覆石墨管 GFAAS 肿瘤患者 Tungstate coated graphite tube, Lithium