期刊文献+

燃烧假人实验室闪火生成系统设计

Design of Flash Fire Generation System in the Method of Thermal Protection Testing
下载PDF
导出
摘要 对国内外燃烧假人实验室相关标准及闪火生成系统进行介绍,结合应用实际提出闪火的设计要求是热流量84kW/m2,持续时间为5s。最后从管道压力调节、燃烧器设计、嵌入式控制系统开发等三个方面介绍了实验室火闪火生成系统的设计实现。 Introduced six flash fire Systems, which provides simulation fire to evaluate the capability of flame resistant clothing. As the method suggested, the requirement of heat flux is 84kW/m2, which lasts 5s. The more detail of pressure adjusting, burner designing, ECS developed are introduced.
出处 《中国个体防护装备》 2010年第6期5-9,共5页 China Personal Protective Equipment
关键词 闪火 燃烧假人 热流量 嵌入式 Flash fire Pyroman Heat flux ECS
  • 相关文献

参考文献8

  • 1ASTM, Standard test method for e- valuation of flame resistant clothing protection against falsh fire simula- tions using an instrumented manikin, 2000.ASTM F 1930.
  • 2NFPA, Standard on Flame-Resis- tant Garments for Protection of In- dustrial Personnel Against Flash Fire, 2006. NFPA 2112.
  • 3http//www.dpp-europe.com/-THER- MO-MAN-R, 79-.html?lang=en.
  • 4SONG, GUOWEN. Modeling Ther- mal Protection Outfits for Fire Ex- posures [M]. North Carolina State University, 2002.
  • 5ENI, Egbe U. Developing Test Proce- dures for Measuring Stored Thermal Energy in Firefighter Protective Clothing[M]. North Carolina State University, 2005.
  • 6http : / / www. bttg. co. uk / PDFs / Manikin_Testing. pdf.
  • 7Matej, Dani. Evaluation of fire pro- tective garments by using instru- mented mannequin and model- based estimation of burn injuries [J], Burns, 2009(35): 970-982.
  • 8Andrew D. EUison, Thermal Manikin Testing of Fire Fighter Ensembles [M]. University of WORCESTER POLYTECHNIC INSTITUTE, 2006.

相关作者