摘要
介绍了低温甲醇洗装置在兖矿榆林能化600kt/a煤制甲醇项目的应用现状,通过一段时间的运行操作,总结低温甲醇洗装置的操作方法和控制要点及CO2指标在非正常情况下调整经验。
The application of Rectisol unit in the 600 kt/a coal-to-methanol project for Yanzhou Yulin was introduced and based on the operation for a period of time the operating method and critical control points as well as the experiences in adjusting CO2 index under abnormal conditions were summarized.
出处
《大氮肥》
CAS
2010年第6期402-404,共3页
Large Scale Nitrogenous Fertilizer Industry
关键词
低温甲醇洗
运行现状
操作要点
总结
Rectisol
running status
operating key points
summary