文章从发电厂、电网、电力负荷的角度出发,分析了近几年来电力系统变压器运行、检修的经验,并分析了水力发电厂自动励磁调节装置的特点,提出了电力系统中水电厂变压器分接开关设计、制造的新观点。
From these respects of power plant,power network and network load,the article analyzes the operation and service experience for power system transformer in recent years,at the same time analyzes the characteristics of automatic excitation device of hydropower plants,and puts forward some new viewpoints for design and manufacture of transformer tapping switch of hydropower plants in electric system.
出处
《贵州水力发电》
2010年第6期63-65,共3页
Guizhou Water Power
关键词
电工技术
变压器
分接开关
电压调整方式
水电厂
electric technique
transformer
tapping switch
voltage adjustment mode