摘要
通信网络防雷是指挥信息系统安全的重要环节。文中介绍了雷电入侵指挥信息系统的3种可能途径及带来的危害,根据指挥信息系统防雷原则与规范,分别对接地系统、电源、线缆布设、等电位等提出了相应的防雷措施,以提高指挥信息系统抗雷击的能力。
The lightning protection of communication networks is essential for the safety of C4I systems.This paper first describes several possible ways by which lightning intrudes communication networks and the possible extent of damage.Then,based on the principles and rules of lightning protection for C4I systems,measures for lightning protection are proposed in respect of the grounding system,the power supply,the laying of the cables and the earthing equipotential to improve the capacity of lightning protection of C4I systems.
出处
《指挥信息系统与技术》
2010年第6期79-82,共4页
Command Information System and Technology
关键词
指挥信息系统
雷击
防雷措施
建筑物防雷
机房防雷
C4I system
communication network
lightning strike
lightning protection measures
lightning protection of buildings
lightning protection of data centre