摘要
通过模型实验 ,探讨了最优混凝搅拌条件。实验结果表明 :最优快速搅拌条件 (GT值 )与原水浊度、投药量、水温等有关 ;最优慢速搅拌条件 (G值 )与投药量等有关 ,慢速搅拌时间 (T值 )宜大于15min。
A model test was conducted in the optimum mixing condition of coagulation. It was found that the optimum flash mixing condition of coagulation(GT) was concerned with turbidity,dose,watertemperate, etc.The optimum low rate mixing(G) was concerned with dose etc.and the low rate mixing time(T) should be above 15min.
出处
《哈尔滨建筑大学学报》
1999年第6期49-52,共4页
Journal of Harbin University of Civil Engineering and Architecture
基金
霍英东教育基金
国家自然科学基金!59508005
关键词
混凝
搅拌
给水处理
coagulation
flash mixing
low rate mixing
feed water treatment