摘要 以处理过的氟罗里硅土为微柱吸附材料,采用流动注射技术进行锑的分离富集,系统地考察了氟罗里硅土微柱对Sb(Ⅲ)的吸附性能,探讨了溶液的pH值、试样流速、试样体积、洗脱液浓度和用量以及干扰离子等因素的影响。实验结果表明,pH值为5.0,试样流速为1.5 mL/min时,氟罗里硅土对Sb(Ⅲ)具有良好的吸附性能,吸附率接近99%,动态饱和吸附容量为6.76 mg/g;选用5 mL 5 mol/L NaOH溶液可将吸附的Sb(Ⅲ)完全洗脱。本法的检出限(3σ)为0.085μg/mL,相对标准偏差为RSD=0.85%(n=11,ρ=10 mg/L)。将本法应用于实际样品中锑的测定,结果满意。 A new method using a microcolumn packed with Florisil as solid-phase extractant has been developed for the determination of Sb(Ⅲ) by spectrophotometry with flow injection technique.The adsorption property of Florisil microcolumn to Sb(Ⅲ) was systematically investigated,and the effects of pH,flow rate and volume of sample solution,concentration and dosage of elution solution and interference ions were discussed.The results showed that Florisil had good adsorption property to Sb(Ⅲ) at pH 5.0 with adsorption rate close to 99 % and dynamic saturation adsorption capacity of 6.76 mg/g when the flow rate of sample solution was 1.5 mL/min.The adsorbed Sb(Ⅲ) could be fully eluted with 5 mL of 5 mol/L NaOH solution.Detection limit(3σ) of this method for Sb(Ⅲ) was 0.085 μg/mL with relative standard deviations of 0.85 %(n=11,ρ=10 mg/L).The proposed method has been applied to the determination of trace amount of Sb(Ⅲ) in actual samples with satisfactory results.
机构地区 辽宁大学化学院
出处 《冶金分析》 CAS CSCD 北大核心 2010年第12期48-52,共5页 Metallurgical Analysis
基金 辽宁省"百千万人才工程"资助项目 辽宁省高等学校优秀人才支持计划(2009R30)
关键词 流动注射 微柱分离 氟罗里硅土 分光光度法 flow injection microcolumn separation Florisil antimony spectrophotometry
  • 相关文献

参考文献11

二级参考文献24

共引文献257

同被引文献28

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部