期刊文献+

分光光度法测定内墙涂料中甲醛的不确定度评定 被引量:3

The uncertainty evaluation for the measurement of formaldehyde content in interior wall coating with spectrometer
下载PDF
导出
摘要 根据GB 18582-2008标准,用分光光度法测定内墙涂料中甲醛含量,并详细分析和评定了测定影响结果的各个分量,认为在本次测定中,不确定度主要来源于标准曲线的拟合、标准物质及重复测试。 This paper described the measurement of the concentration of formaldehyde(CH2O) in the inner coating materials with a spectrometer according to the standard of GB 18582-008.It also analyzes and defines the integrants which can generate noise making up uncertainty of this measurement,and it comes to a conclusion that uncertainty mainly arose from the simulation to standard curve,normal integrants and the repeatability of measurement.
作者 林美
出处 《福建建设科技》 2010年第6期43-45,共3页 Fujian Construction Science & Technology
关键词 甲醛 不确定度 formaldehyde Uncertainty
  • 相关文献

参考文献4

  • 1JJF1059-1999.测量不确定度评定和表示.[S].,..
  • 2测量不确定度评定与表示指南.北京:中国计量出版社,2000.4
  • 3[3]中国实验室国家认可委员会.化学分析中不确定度的评定指南[M].北京:中国计量出版社,2002:11~60.
  • 4GB18582-2008室内装饰装修材料内墙涂料中有害物质限量.

共引文献22

同被引文献17

引证文献3

二级引证文献7