在碳钢电极工作面与环氧树脂交界处涂覆一层室温硫化硅橡胶,研究了有、无硅橡胶处理的两种碳钢电极的电化学行为。结果表明,涂覆硅橡胶能够有效避免缝隙腐蚀的发生,提高试验结果的准确性。同时讨论了室温硫化硅橡胶与碳钢电极之间的作用机理。
The junction of working face and epoxy was coated with a layer of room temperature vulanized(RTV) silicone rubber. The electrochemical behaviors of the treated and un-treated carbon steel electrodes were studied. The results showed that the treatment could prevent the electrode from crevice corrosion effectively. The mechanism was discussed.
出处
《腐蚀与防护》
CAS
北大核心
2011年第2期116-118,共3页
Corrosion & Protection
关键词
碳钢电极
缝隙腐蚀
室温硫化硅橡胶
carbon steel electrode
crevice corrosion
room temperature vulcanized (RTV) silicone rubber