摘要 研制用于检测甲拌磷残留量的间接竞争ELISA试剂盒。甲拌磷包被抗原的最佳工作质量浓度为4mg/L,抗体的最佳稀释倍数为8000,甲拌磷多克隆抗体交叉反应率小于20%,甲拌磷抑制率回归曲线为y=18.846x+6.9949,在1~5000μg/L范围内呈线性关系,检测限为4.90μg/L,IC50为191.37μg/L。甲拌磷试剂盒的添加回收率均高于75%,供试样品检测结果的批内和批间变异系数均低于10%。试剂盒在4℃或-20℃下有效期为270d。 An indirect enzyme-linked immunosorbent assay(ELISA)kit was developed to monitor phorate residue. The optimal concentration of coating antigen was 4 mg/L and the optimal dilution ratio of antibody was 8000. The cross-reaction ratio was less than 20%. The regression equation of inhibition rate for phorate was y = 18.846x+6.9949 with a linear detection range of 1-5000μg/L. Results indicated that the detection limit was 4.90μg/L and IC50 was 191.37μg/L. The recovery rates were higher than 75%. The intra-assay and inter-assay coefficients were less than 10%. The developed kit can be stored at 4℃ or-20 ℃ for 270 days.
出处 《食品科学》 CAS CSCD 北大核心 2011年第4期284-287,共4页 Food Science
基金 沈阳农业大学中、青年硕士生导师资助项目
关键词 甲拌磷 残留 酶联免疫吸附测定法 试剂盒 phorate residue enzyme-linked immunosorbent assay(ELISA) kit