期刊文献+

神经导航下切除海绵状血管瘤 被引量:14

Neuronavigation for the resection of intracranial cavernous angiomas
原文传递
导出
摘要 目的介绍StealthStation神经导航系统在颅内海绵状血管瘤手术中的应用。方法在6例以癫痫起病的海绵状血管瘤手术中,StealthStation神经导航系统提供手术野和CT影像的实时吻合、术中导航,其中4例锁眼外科手术,2例皮瓣开颅手术。结果6例手术均导航定位全切病灶及其周边含铁血黄素沉着带、胶质增生和钙化,无手术并发症,术后癫痫消失。平均注册误差165~453mm,每10cm预期准确性182~328mm,持续准确性为050~345mm。结论在海绵状血管瘤手术中,应用StealthStation系统导航,准确性高,可靠性强。 Objective To evaluate the use of the Stealth Station neuronavigator in conjunction with preoperative computerized tomography (CT) in the resection of intracranial cavernous angiomas(CAs).WT5HZMethods The Stealth Station neuronavigator was used to provide realtime correlation of the operating field and computerized images in 6 patients with CAs. All of them suffered from epileptic seizures.T5HZResults Neuronavigationguided lesionectomy with removal of hemosiderin deposition, gliosis and calsification in all cases was performed precisely. Mean fiducial error,predicted accuracy at 10 cm, and sustained accuracy ranged from 165 to 453 mm, 182 to 328 mm, and 050 to 345 mm, respectively. Conclusions The Stealth Station neuronavigator is reliable and accurate in the resection of CAs.
出处 《中华外科杂志》 CAS CSCD 北大核心 1999年第5期289-291,共3页 Chinese Journal of Surgery
关键词 血管瘤 海绵状 神经导航 外科手术 中枢神经 Hemangiomas,cavernousNeuronavigate
  • 相关文献

参考文献4

二级参考文献15

  • 1罗世祺,中华神经外科杂志,1993年,9卷,6期,318页
  • 2沈天真,中枢神经系统计算机体层摄影(CT)和磁共振成像(MRI),1992年,156页
  • 3何理盛,国外医学神经病学、神经外科学分册,1991年,18卷,4期,178页
  • 4唐镇生,上海医学,1988年,11卷,3期,167页
  • 5郑安琪,中华神经精神科杂志,1984年,17卷,1期,16页
  • 6Roberts DW,Strohbehn JW,Hatch JF,et al. A frameless stereoraxic integration of computerized tomographic imaging and the operating microscope. J Neurosurg,1986,65:545-548.
  • 7Watanabe E, Watanabe T, Manaka S,et al. Three-dimentional digitizer ( neuro-navigator ) , A new equipment for CT-guided stereotaxic surgery. Surg Neurol, 1987,27:543-547.
  • 8Ziarecuich SJ , Tebo SA, Long DM, et al. Framelcss stereotaxic integratioa of CT imaging data, Accuracy and initial appticaliorts. Radiology, 1993, 188:735-745.
  • 9Golfinos JG, Fitzpatrick BC, Smith LR, et al. Clinical use of a frameless stereotactie arm: results of 325 cases.J Netlrosurg, 1995, 83:197-205.
  • 10Patel N , Saademan DR , Colly M , et al. Interative imageguided surgery of the spine use of the ISG/ELekta Viewing Wand to aid intraopcratine Localization of a sacral osteoblastomea, BJ Neurosurg, 1997, 11: 60-64.

共引文献29

同被引文献102

引证文献14

二级引证文献71