摘要 用血凝抑制试验和间接ELISA两种方法检测乙脑阳性血清均呈阳性反应,检测乙脑阴性血清均呈阴性反应。用间接ELISA对来自9个猪场74份送检血清进行了猪乙脑病毒(Japanese encephalitis virus,JEV)抗体检测,并与血凝抑制试验(HI)进行对比,两种方法检测总符合率为85.1%(63/74),经统计分析,检测结果差异不显著(P>0.05)。对来自无猪乙脑病猪场24头健康猪的血清进行检测,两种方法结果均为阴性,符合率为100%。对10份阳性血清进行检测,ELISA检测效价较HI效价高,表明ELISA比HI敏感。结果表明,ELISA与HI检测结果相符,前者更适用于猪血清中乙脑IgG抗体的大规模检测。 The results were positive and negative to JEV when positive serum and negative serum were detected by both HI and indirect ELISA,respectively.74 sera from 9 farms were detected by ELISA and HI,the coincidence rate of both methods was 85.1%(63/74).No significant difference was found between the two methods(P0.05).Furthermore,the results of 24 serum samples from healthy pigs in farm without suffering from JE were negative by HI and ELISA by testing,the coincident rate of both methods was 100%.The results of detecting 10 positive sera were more sensitive by ELISA than by HI.It indicated that indirect ELISA was the same as HI to detect antibody against JEV in swine sera and more suitable for large-scale detection of IgG antibodies against Japanese encephalitis in pig's sera.
出处 《中国畜牧兽医》 CAS 北大核心 2011年第2期157-159,共3页 China Animal Husbandry & Veterinary Medicine
基金 "九五"国家科学技术攻关计划生物技术项目(96-C01-04-03) 湖南省教育厅一般项目(07C356)
关键词 乙型脑炎 ELISA 血凝抑制试验 比较 Japanese encephalitis ELISA HI comparison
  • 相关文献

参考文献3

  • 1王治方,郭成留,张清华,徐引弟,张玉杨.两种不同方法对猪瘟免疫效果评估对比试验[J].中国畜牧兽医,2007,34(9):99-100. 被引量:9
  • 2自登云,陈伯权,俞永新.虫媒病毒与虫媒病毒病[M].昆明:云南科技出版社,1994,151-155.
  • 3Jia X L, Chen H C, Wang X, et al. Quantitative and qualitative study of enzyme linked immunosorbent assay to detect IgG against Japanese encephalitis virus in swine sera. Veterinary Research Communications,2005,29(2) :159--169.

共引文献13

同被引文献97

引证文献5

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部