期刊文献+

湿式空气氧化过程中氧气、二氧化碳和水蒸气分压的理论 被引量:2

On the theory of partial pressure of oxygen,carbon dioxide and water vapor in wet air oxidation(WAO).
下载PDF
导出
摘要 介绍了亨利常数随温度、压力变化的经验公式,并采用湿式空气氧化( W A O) 工艺处理城市污水厂活性污泥,验证了湿式氧化过程中亨利常数经验估算公式,以期为湿式氧化工艺设计和运行实践提供依据.结果表明,在180 ℃时,氧气的初始分压为0 .98 M Pa,氧气和二氧化碳的亨利常数分别为2 .5778 ×109 、5 .9894 ×109 N/ m2 . In this paper,the empirical formula of Herrey's constant of pressure of oxygen , carbon dioxide and water vapor with temperature and pressure is dealed with;and the treatment of waste activated sludge from municipal sewage plant by using WAO(wet air oxidation) is studied. It is useful for the design and operation of this WAO process. The influences of oxygen , carbon dioxide and water vapor on the system were also investigated. The results show that the Henry's constant of oxygen and carbon dioxide at 180℃and 0.98MPa initial pressure is 2.5778×109N/m 2 and 5.9894×109 N/m 2 respectively.
出处 《中国环境科学》 EI CAS CSCD 北大核心 1999年第4期342-344,共3页 China Environmental Science
基金 国家自然科学基金
关键词 活性污泥 湿式空气氧化 亨利常数 污水处理 activated sludge wet air oxidation(WAO) Henry's constant