钢-高性能混凝土组合桥塔受力性能试验研究 被引量:4

Experimental research on structure behaviors of steel and high performance concrete composite bridge tower
下载PDF
导出
摘要 针对钢-高性能混凝土组合桥塔节段进行了轴心受压试验,研究组合桥塔的受力性能,得到了模型破坏时的承载力和破坏形态,分析了其应变及变形规律。参考相关规范和规程,对组合桥塔的承载力进行了计算,并在试验基础上提出了组合桥塔承载力的计算方法。结果表明:壁板的局部失稳对于组合桥塔的承载力影响较大;在计算组合桥塔的轴压承载力时,需根据壁板局部失稳的情况加以区分,可以采用矩形钢管混凝土组合结构规范中的公式或本文提出的方法进行计算。 An axial compression test was practiced on a steel and high-performance-concrete composite bridge tower segment in order to study the structure behavior of the composite towers. From the test, the limit load-capacity and failure mode of the specimen were obtained, and the regularity of the strain and deformation were analyzed. The limit load-capacity was calculated according to the related codes of China and other countries, and two other calculate methods were proposed based on the test. The result shows that the local buckling of the panels has great influence on the limit load capacity of the composite towers, when calculating the axial compression limit load-capacity, the local buckling of the panels must be determined firstly, and then adopting the formula for rectangle concrete filled steel tubular structures in design codes or the methods proposed in this paper. 2 tabs, 9 figs, 13 refs.
出处 《长安大学学报(自然科学版)》 EI CAS CSCD 北大核心 2011年第1期51-58,共8页 Journal of Chang’an University(Natural Science Edition)
基金 霍英东青年教师基金资助项目(101078) 教育部新世纪优秀人才支持计划资助项目(NCET-07-0102)
关键词 桥梁工程 钢一高性能混凝土 组合桥塔 局部稳定 bridge engineering steel and high-performance-concrete composite bridge tower local buckling