期刊文献+

线型红外光束感烟探测器的响应性能研究 被引量:4

The response performance of linear infrared beam smoke detector
下载PDF
导出
摘要 利用CFD场模拟软件FDS,对线型红外光束感烟探测器的响应性能进行预测,研究火源类型、火源功率、探测器设置高度、水平安装位置等因素对报警时间的影响。结果表明,相同高度处火灾探测器的响应时间随火源与探测器水平距离的增大而增大;火源功率对探测器的影响随距离增大而减小;火源类型不同,探测器响应数量差异很大。 Utilizing the CFD field simulating software FDS, to predict the response performance of linear infrared beam smoke detector, and research the influence of alarm time of the fire source type, fire source power, height and horizontal position to the detector. Results showed that, given the same height, the response time of detector increases as the distance between the detector and the fire source increases; the influence of fire source power to the detectors decrease as the distance increase; the number of detectors responded varies with the fire source type.
出处 《消防科学与技术》 CAS 北大核心 2011年第2期137-140,共4页 Fire Science and Technology
基金 国家"十一五"科技支撑计划项目(2006BAJ13B03)
关键词 FDS 红外光束 响应性能 感烟探测器 FDS infrared beam response performance smoke detector
  • 相关文献

参考文献8

  • 1GB50116-98.火灾自动报警系统设计规范[S].[S].,..
  • 2GB14003-2005线型光束感烟火灾探测器[S].
  • 3周全会.线型光束感烟火灾探测器在大空间建筑的应用[J].建筑电气,2009,28(2):52-54. 被引量:6
  • 4宋珍,翁立坚,刘凯.远距离线型红外光束感烟火灾探测技术研究[C].中国科协年会,2006.
  • 5Donald D Anderso.Laser spot detector technology for early warning of smoke[C].11th International Conferenz on Automatic Firc Detection AUBE'99,Duisburg,Germany,1999.
  • 6Matthew Brookman,Frederick W Mowrer and James A Milke.Validation of a smoke detection performance prediction methodology[J].Volume 1.Characterization of incipient fire sources[M].Fire Protection Research Foundation,2008.
  • 7许彬,张永明,方俊,马绥华,刘勇.正庚烷热释放速率测量与研究[J].消防科学与技术,2006,25(3):304-307. 被引量:26
  • 8肖泽南.红外光束感烟探测器探测时间计算[J].消防技术与产品信息,2008,21(8):16-18. 被引量:1

二级参考文献20

  • 1张和平,王蔚,杨昀,徐亮.全尺寸墙角火实验中木工板表面火蔓延研究[J].燃烧科学与技术,2004,10(6):506-510. 被引量:11
  • 2GB50116-1998.火灾自动报警系统设计规范[S].[S].,..
  • 3V Babrauskas, et al. Heat release in fires, London[M]. Elsevier Applied Science London and New York: Library of Congress Cataloging-in-Publication Data, 1992.
  • 4ISO 9705, Fire Tests-Full Scale Room Test for Surface Products[S]. International Standards Organization (ISO),Geneva, 1993.
  • 5C Huggett. Estimation of rate of heat release by means of oxygen consumption measurements[J]. Fire and Materials, 1980,4 ( 1 ):61-65.
  • 6Life Safety Code, NFPA 101, 2000[S]
  • 7Guide for Smoke Management System in Mall, Atria, and Large Area, NFPA 92B, 2000[S].
  • 8National Fire Alarm Code, NFPA 72, 2002[S].
  • 9SFPE Handbook of Fire Protection Engineering [ M ], National Fire Protection Association, Quincy, MA, 1995.
  • 10Fire Protection Handbook [ M ], 19th edition, National Fire Protection Association, Quincy, Massachusetts,2003.

共引文献239

同被引文献19

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部