期刊文献+

离子迁移谱技术及其化学校准物概述 被引量:2

Technique of ion mobility spectrometry and summary of its chemical calibrants
下载PDF
导出
摘要 离子迁移谱技术(IMS)是一种现场痕量探测技术,被广泛地用于反恐安检等痕量探测领域。IMS探测仪的正常工作离不开一些特定化学物质作为校准物,但是国内鲜有报道提及该类物质,概述了数种化学物质在作为IMS校准物时的一些特性。 Ion mobility spectrometry(IMS) has recently undergone significant expansion in terms of the number of users and applications,particularly in the security domain.The operation system cannot run smoothly without certain chemical compounds,named calibrants.Although several IMS reference standards have been proposed,there are no currently universally recognized reference standards for the calibration and evaluation of mobility spectrometers.This article describes current practices and the literature on several chemical standards for validating IMS systems in both positive and negative ion modes.
出处 《化学试剂》 CAS CSCD 北大核心 2011年第2期129-132,共4页 Chemical Reagents
关键词 离子迁移谱 校准物 ion mobility spectrometry(IMS) chemical calibrants
  • 相关文献

参考文献16

  • 1EICEMAN G A, KARPAS Z. Ion mobility spectrometry [ M ]. Florida : CRC Press, 1994.
  • 2袁曦,郑健,施亮,蒋大真.用于现场痕量检测的IMS爆炸物探测仪研究[J].核技术,2006,29(7):544-547. 被引量:16
  • 3EWING R G,ATKINSON D A,EICEMAN G A,et al. A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds [ J ]. Talanta ,2001,54 ( 3 ) :515-529.
  • 4吕勇杰,朱学梅,郑健,陈扬骎.应用离子迁移率谱仪技术快速检测毒品的研究[J].核技术,2007,30(10):818-822. 被引量:8
  • 5LAWRENCE A H. Ion mobility spectrometry/mass spectrometry of some prescription and illicit drugs [ J ]. Anal. Chem. ,1986,58(6) :1 269-1 272.
  • 6王学峰,叶伟,彭凤武.离子迁移谱技术及其在化学战剂侦检中的应用[J].化学分析计量,2007,16(4):76-79. 被引量:6
  • 7SFEROPOULOS R. A review of chemical warfare agent (CWA) detector technologies and commercial-off-theshelf items[ M ]. Victoria: Defence Science and Technology Organisation(DSTO) ,2008.
  • 8成云飞,朱学梅,朱丽英,等.离子迁移谱仪在爆炸物检测方面的应用研究[C]//防爆安检技术论文集.2008:83-88.
  • 9ARSHADI M, KEBARLE P. Hydration of OH - and O2- in the gas phase, comparative solvation of OH - by water and the hydrogen halides, effects of acidity [ J ]. J. Phys. Chem. ,1970,74(7) :1 483-1 485.
  • 10徐淑武,郑健,毕志毅,陈扬骎.离子迁移谱检测技术及其应用[J].物理,2003,32(8):539-542. 被引量:19

二级参考文献51

共引文献39

同被引文献36

  • 1朱弘.离子迁移谱探测仪技术的研究[J].自动化与仪器仪表,2006(3):65-67. 被引量:6
  • 2袁曦,郑健,施亮,蒋大真.用于现场痕量检测的IMS爆炸物探测仪研究[J].核技术,2006,29(7):544-547. 被引量:16
  • 3王学峰,叶伟,彭凤武.离子迁移谱技术及其在化学战剂侦检中的应用[J].化学分析计量,2007,16(4):76-79. 被引量:6
  • 4吕勇杰,朱学梅,郑健,陈扬骎.应用离子迁移率谱仪技术快速检测毒品的研究[J].核技术,2007,30(10):818-822. 被引量:8
  • 5Isabel Márquez-Sillero,Soledad Cárdenas,Miguel Valcárcel.Direct determination of 2,4,6-tricholoroanisole in wines by single-drop ionic liquid microextraction coupled with multicapillary column separation and ion mobility spectrometry detection[J]. Journal of Chromatography A . 2011 (42)
  • 6M. Menéndez,R. Garrido-Delgado,L. Arce,M. Valcárcel.Direct determination of volatile analytes from solid samples by UV-ion mobility spectrometry[J]. Journal of Chromatography A . 2008 (1)
  • 7M.T. Jafari,T. Khayamian,V. Shaer,N. Zarei.Determination of veterinary drug residues in chicken meat using corona discharge ion mobility spectrometry[J]. Analytica Chimica Acta . 2006 (1)
  • 8Zeev Karpas,Boris Tilman,Rachel Gdalevsky,Avraham Lorber.Determination of volatile biogenic amines in muscle food products by ion mobility spectrometry[J]. Analytica Chimica Acta . 2002 (2)
  • 9R.A Miller,G.A Eiceman,E.G Nazarov,A.T King.A novel micromachined high-field asymmetric waveform-ion mobility spectrometer[J]. Sensors & Actuators: B. Chemical . 2000 (3)
  • 10JI Baumbach,S Sielemann,Z Xie,H Schmidt.Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source. Analytical Biochemistry . 2003

引证文献2

二级引证文献17

相关作者