摘要
简要介绍了沈阳市府恒隆广场商场部分底板施工中泵送混凝土泵管超过300 m情况下,进行了泵送混凝土质量控制的工作要点以及混凝土施工工艺的控制。对于同类施工具有一定借鉴意义。
The length of pump concrete line is over 400 meters in the emporium part of the tallest building in northeast. Under the circumstances, this paper presents about the main point of pump concrete quality control and the control of concrete construction technology. The reference is given for the similar project.
出处
《建筑技术开发》
2011年第2期13-14,共2页
Building Technology Development
关键词
泵送混凝土
质量控制
配合比
坍落度
pumping concrete
quality control
mixture ratio
slump